Polling Settings

From MiOS
(Difference between revisions)
Jump to: navigation, search
(New page: Polling is the process where Vera tries to ask a Z-Wave device for its current status, like if its on or off, at what temperature, and so on. This is how Vera knows when the status of a d...)

Revision as of 02:55, 5 January 2009

Polling is the process where Vera tries to ask a Z-Wave device for its current status, like if its on or off, at what temperature, and so on. This is how Vera knows when the status of a device changes, such as when the temperature has changed if it's a thermostat, or if you manually turned on or off a light. Normally Vera attempts to poll one Z-Wave device every 10 seconds, and Vera polls the devices in order until Vera has polled all of them. So the delay between polling nodes depends on how many nodes you have. If you have 6 nodes, each node will be polled once a minute, and if you manually turn a light off, within a minute or so Vera's dashboard will show the light is off. But, if you have 100 ZWave devices, it can take 16 minutes before Vera has polled them all. You can change the polling behavior by going to the devices tab on Vera's setup page and selecting More Z-Wave options.

--todoab: finish

Personal tools