Leviton LED Debugging
Micasaverde (Talk | contribs) (New page: On the 'Scenes' tab for a scene/zone controller if you check the box: "Automatically turn on/off the scene indicator lights" then MiOS should manage the LED's for you turning them on and o...) |
m |
||
(One intermediate revision by one user not shown) | |||
Line 1: | Line 1: | ||
+ | [[Category:Development]] | ||
+ | [[Category:How To]] | ||
+ | |||
+ | '''Leviton LED debugging''' | ||
+ | |||
On the 'Scenes' tab for a scene/zone controller if you check the box: "Automatically turn on/off the scene indicator lights" then MiOS should manage the LED's for you turning them on and off. If that's not happening, the first thing to do is be sure MiOS even CAN turn the lights on/off. The command to turn the LED's on/off is not exposed in the UI because it's not something users normally would do. But, you can do it manually. The easiest way to do this is to open a web browser and go to this URL: | On the 'Scenes' tab for a scene/zone controller if you check the box: "Automatically turn on/off the scene indicator lights" then MiOS should manage the LED's for you turning them on and off. If that's not happening, the first thing to do is be sure MiOS even CAN turn the lights on/off. The command to turn the LED's on/off is not exposed in the UI because it's not something users normally would do. But, you can do it manually. The easiest way to do this is to open a web browser and go to this URL: | ||
Line 43: | Line 48: | ||
The run scene comes in at 21:07:55.329, which triggers the 'on' for the light at 21:07:55.332, which at 21:07:56.717 causes the scene to be marked 'active' (ie now=1 where 1=active). At 21:07:56.718 it decides to set button #1 to value 1 (green). At 21:07:56.784 the job to turn the light on has finished and at 21:07:57.247 the job to adjust the scene LED is finished. | The run scene comes in at 21:07:55.329, which triggers the 'on' for the light at 21:07:55.332, which at 21:07:56.717 causes the scene to be marked 'active' (ie now=1 where 1=active). At 21:07:56.718 it decides to set button #1 to value 1 (green). At 21:07:56.784 the job to turn the light on has finished and at 21:07:57.247 the job to adjust the scene LED is finished. | ||
+ | |||
+ | Next I turn the light off, and you can see the scene becomes inactive and the scene indicator goes off: | ||
+ | |||
+ | 08 08/13/10 21:11:24.599 JobHandler_LuaUPnP::HandleActionRequest device: 5 service: urn:upnp-org:serviceId:Dimming1 action: SetLoadLevelTarget <0x680e> | ||
+ | 08 08/13/10 21:11:24.600 JobHandler_LuaUPnP::HandleActionRequest argument DeviceNum=5 <0x680e> | ||
+ | 08 08/13/10 21:11:24.601 JobHandler_LuaUPnP::HandleActionRequest argument serviceId=urn:upnp-org:serviceId:Dimming1 <0x680e> | ||
+ | 08 08/13/10 21:11:24.601 JobHandler_LuaUPnP::HandleActionRequest argument action=SetLoadLevelTarget <0x680e> | ||
+ | 08 08/13/10 21:11:24.602 JobHandler_LuaUPnP::HandleActionRequest argument newLoadlevelTarget=0 <0x680e> | ||
+ | 10 08/13/10 21:11:26.019 Scene::UpdateIsActive 9 Living On is now 0 <0x803> | ||
+ | 10 08/13/10 21:11:26.020 ZWaveNode::SetSceneControllerIndicator button: 1 value 0 state was: 99 now: 98 <0x803> | ||
+ | 04 08/13/10 21:11:26.142 <Job ID="38" Name="Level 0 node 4" Created="10-08-13 21:11:24" Started="10-08-13 21:11:24" Completed="10-08-13 21:11:26" Duration="1.397052000" Runtime="1.387392000" Status="Successful" LastNote="Transmit was ok" Node="4" Device="5" NodeType="ZWaveDimmableLight" NodeDescription="Dining"/> <0x803> | ||
+ | 04 08/13/10 21:11:26.480 <Job ID="39" Name="sc_ind 5.1" Created="10-08-13 21:11:26" Started="10-08-13 21:11:26" Completed="10-08-13 21:11:26" Duration="0.376782000" Runtime="0.331100000" Status="Successful" LastNote="Transmit was ok" Node="5" Device="24" NodeType="ZWaveController" NodeDescription="_4 button zone controller (scene)"/> <0x402> |
Latest revision as of 07:01, 27 May 2011
Leviton LED debugging
On the 'Scenes' tab for a scene/zone controller if you check the box: "Automatically turn on/off the scene indicator lights" then MiOS should manage the LED's for you turning them on and off. If that's not happening, the first thing to do is be sure MiOS even CAN turn the lights on/off. The command to turn the LED's on/off is not exposed in the UI because it's not something users normally would do. But, you can do it manually. The easiest way to do this is to open a web browser and go to this URL:
http://[ip]:3480/data_request?id=lu_invoke
so if the IP of vera is 192.168.2.117, open: http://192.168.2.117:3480/data_request?id=lu_invoke
Then select the scene controller, and then select "SetLight (newValue,Indicator)". Don't worry about the error message, the URL will look like this:
http://192.168.2.117:3480/data_request?id=lu_action&DeviceNum=24&serviceId=urn:micasaverde-com:serviceId:SceneControllerLED1&action=SetLight&newValue=&Indicator=
Edit it and after newValue= put in 0,1,2 or 3 where 0=off, 1=green, 2=red, 3=orange. After the Indicator= put the button number, such as 4 for button #4. So if your scene controller is device #24 and you want to make button #2 go orange, do:
http://192.168.2.117:3480/data_request?id=lu_action&DeviceNum=24&serviceId=urn:micasaverde-com:serviceId:SceneControllerLED1&action=SetLight&newValue=3&Indicator=2
You may also want to refer to this page to see how you can follow this in the logs: Logs and you'll see the if it's working the logs should show something like this:
root@MiOS_10266:/tmp/log/cmh# tail -f LuaUPnP.log | grep "^04\|^08"
08 08/13/10 20:59:34.538 JobHandler_LuaUPnP::HandleActionRequest device: 24 service: urn:micasaverde-com:serviceId:SceneControllerLED1 action: SetLight <0x1300e> 08 08/13/10 20:59:34.538 JobHandler_LuaUPnP::HandleActionRequest argument DeviceNum=24 <0x1300e> 08 08/13/10 20:59:34.539 JobHandler_LuaUPnP::HandleActionRequest argument serviceId=urn:micasaverde-com:serviceId:SceneControllerLED1 <0x1300e> 08 08/13/10 20:59:34.540 JobHandler_LuaUPnP::HandleActionRequest argument action=SetLight <0x1300e> 08 08/13/10 20:59:34.540 JobHandler_LuaUPnP::HandleActionRequest argument newValue=2 <0x1300e> 08 08/13/10 20:59:34.541 JobHandler_LuaUPnP::HandleActionRequest argument Indicator=3 <0x1300e> 04 08/13/10 20:59:35.749 <Job ID="24" Name="scene_ind_5 node 5" Created="10-08-13 20:59:34" Started="10-08-13 20:59:34" Completed="10-08-13 20:59:35" Duration="1.151778000" Runtime="1.143690000" Status="Successful" LastNote="Transmit was ok" Node="5" Device="24" NodeType="ZWaveController" NodeDescription="_4 button zone controller (scene)"/> <0x803>
If the LED indicators do not turn on and off, something is wrong. If they do, then MiOS can control the scene indicators, and the question is simply why are they not going on and off. The best thing to do is go to Advanced, Logs in the toolbox and check 'Verbose Logging' and then follow the Logs with this filter:
tail -f LuaUPnP.log | grep "^04\|^08\|UpdateIsActive\|SetSceneControllerIndicator"
Here is an example of a scene called "Living On" which turns on device #5 and which is bound to button #1 on the scene controller #24 (node 5):
root@MiOS_10266:/tmp/log/cmh# tail -f LuaUPnP.log | grep "^04\|^08\|UpdateIsActive\|SetSceneControllerIndicator" 08 08/13/10 21:07:55.329 JobHandler_LuaUPnP::HandleActionRequest device: 0 service: urn:micasaverde-com:serviceId:HomeAutomationGateway1 action: RunScene <0x2c0c> 08 08/13/10 21:07:55.329 JobHandler_LuaUPnP::HandleActionRequest argument SceneNum=9 <0x2c0c> 08 08/13/10 21:07:55.330 Scene::RunScene running 9 Living On <0x2c0c> 08 08/13/10 21:07:55.332 JobHandler_LuaUPnP::HandleActionRequest device: 5 service: urn:upnp-org:serviceId:SwitchPower1 action: SetTarget <0x2c0c> 08 08/13/10 21:07:55.333 JobHandler_LuaUPnP::HandleActionRequest argument newTargetValue=1 <0x2c0c> 10 08/13/10 21:07:56.717 Scene::UpdateIsActive 9 Living On is now 1 <0x803> 10 08/13/10 21:07:56.718 ZWaveNode::SetSceneControllerIndicator button: 1 value 1 state was: 98 now: 99 <0x803> 04 08/13/10 21:07:56.784 <Job ID="32" Name="Level 99 node 4" Created="10-08-13 21:07:55" Started="10-08-13 21:07:55" Completed="10-08-13 21:07:56" Duration="1.359941000" Runtime="1.355686000" Status="Successful" LastNote="Transmit was ok" Node="4" Device="5" NodeType="ZWaveDimmableLight" NodeDescription="Dining"/> <0x803> 04 08/13/10 21:07:57.247 <Job ID="33" Name="sc_ind 5.1" Created="10-08-13 21:07:56" Started="10-08-13 21:07:56" Completed="10-08-13 21:07:57" Duration="0.504798000" Runtime="0.452909000" Status="Successful" LastNote="Transmit was ok" Node="5" Device="24" NodeType="ZWaveController" NodeDescription="_4 button zone controller (scene)"/> <0x803>
The run scene comes in at 21:07:55.329, which triggers the 'on' for the light at 21:07:55.332, which at 21:07:56.717 causes the scene to be marked 'active' (ie now=1 where 1=active). At 21:07:56.718 it decides to set button #1 to value 1 (green). At 21:07:56.784 the job to turn the light on has finished and at 21:07:57.247 the job to adjust the scene LED is finished.
Next I turn the light off, and you can see the scene becomes inactive and the scene indicator goes off:
08 08/13/10 21:11:24.599 JobHandler_LuaUPnP::HandleActionRequest device: 5 service: urn:upnp-org:serviceId:Dimming1 action: SetLoadLevelTarget <0x680e> 08 08/13/10 21:11:24.600 JobHandler_LuaUPnP::HandleActionRequest argument DeviceNum=5 <0x680e> 08 08/13/10 21:11:24.601 JobHandler_LuaUPnP::HandleActionRequest argument serviceId=urn:upnp-org:serviceId:Dimming1 <0x680e> 08 08/13/10 21:11:24.601 JobHandler_LuaUPnP::HandleActionRequest argument action=SetLoadLevelTarget <0x680e> 08 08/13/10 21:11:24.602 JobHandler_LuaUPnP::HandleActionRequest argument newLoadlevelTarget=0 <0x680e> 10 08/13/10 21:11:26.019 Scene::UpdateIsActive 9 Living On is now 0 <0x803> 10 08/13/10 21:11:26.020 ZWaveNode::SetSceneControllerIndicator button: 1 value 0 state was: 99 now: 98 <0x803> 04 08/13/10 21:11:26.142 <Job ID="38" Name="Level 0 node 4" Created="10-08-13 21:11:24" Started="10-08-13 21:11:24" Completed="10-08-13 21:11:26" Duration="1.397052000" Runtime="1.387392000" Status="Successful" LastNote="Transmit was ok" Node="4" Device="5" NodeType="ZWaveDimmableLight" NodeDescription="Dining"/> <0x803> 04 08/13/10 21:11:26.480 <Job ID="39" Name="sc_ind 5.1" Created="10-08-13 21:11:26" Started="10-08-13 21:11:26" Completed="10-08-13 21:11:26" Duration="0.376782000" Runtime="0.331100000" Status="Successful" LastNote="Transmit was ok" Node="5" Device="24" NodeType="ZWaveController" NodeDescription="_4 button zone controller (scene)"/> <0x402>