ThermostatModes
The user interface exposes the basic commonly used thermostat modes. However, there are some extra modes which some thermostats may support that are not shown in the UI. To use them, you will need to create a scene, and under the Advanced tab, choose the thermostat, then for the list of commands, under the heading "urn:upnp-org:serviceId:HVAC_UserOperatingMode1" choose the action "SetModeTarget", and in the variable "NewModeTarget", enter one of the following strings without the " marks. You can then run the scene to go into the mode.:
"Auxiliary" which is ZWave thermostat mode #4
"Resume" which is ZWave thermostat mode #5
"FanOnly" which is ZWave thermostat mode #6
"Furnace" which is ZWave thermostat mode #7
"DryAir" which is ZWave thermostat mode #8
"MoistAir" which is ZWave thermostat mode #9
"Auto2" which is ZWave thermostat mode #10
"EnergySaveHeat" which is ZWave thermostat mode #11
"EnergySaveCool" which is ZWave thermostat mode #12
"Away" which is ZWave thermostat mode #13