SmartSwitch

From MiOS
(Difference between revisions)
Jump to: navigation, search
(Created page with "{| align="left" cellspacing="1" cellpadding="1" border="1" style="width: 640px; height: 251px;" |- ! scope="col" | Param. # <br> ! scope="col" | Description ! scope="col" | Defau...")

Revision as of 14:57, 8 February 2012

Param. #
Description Default Value
Allowed Values
90
Enables/disables parameter 91 and 92 below
1

0 - Disabled

1 - Enabled

91
Minimum change in wattage (in watts) for a report to be sent
50
1 - 65535
92
Minimum change in wattage percent (in percentage) for a report to be sent
10
1 - 255
101
Report 1
4 (4 = Watts)
4, 8
102
Report 2
8 (8 = KWH)
4, 8
111
The interval of sending Report 1 (in seconds)
1
1 - 65535
112
The interval of sending Report 2 (in seconds) 60
1 - 65535