Luup CP Mandatory Types

From MiOS
Revision as of 02:50, 13 June 2009 by Micasaverde (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

To be considered fully functional a UPnP Control Point must support for the following device types and services/actions:

Contents

BinaryLight

Must have a graphical representation of on/off which corresponds to the SwitchPower/Status variable

Mandatory Services/Actions: SwitchPower/SetTarget

DimmableLight

Must have a graphical representation of a dimming control, such as a slider which corresponds Dimming/LoadLevelStatus variable, in addition to the requirements for a BinaryLight.

Mandatory Services/Actions in addition to BinaryLight: Dimming/SetLoadLevelTarget

HVAC_ZoneThermostat

Must show the current heat+cool setpoints and ambient temperature as well as the operating mode and fan mode.

Mandatory Services/Actions: HVAC_UserOperatingMode/SetModeTarget, HVAC_FanOperatingMode/SetMode, TemperatureSetpoint/SetCurrentSetpoint (both heat & cool)

MotionSensor

Must show the current arm/bypass state as well as the Tripped state.

Mandatory Services/Actions: MotionSensor/SetArmedStatus

LightSensor/HumiditySensor/TemperatureSensor

Must show the current value.

DoorLock

Must show the current locked/unlocked state.

Mandatory Services/Actions: DoorLock/SetTarget, DoorLock/SetUserCode, DoorLock/ClearUserCode

DigitalSecurityCamera

Must be able to show the current image from the camera with auto-refresh.

Mandatory Services/Actions: PanTiltZoom1/MoveLeft,Right,Up,Down,In,Out

Additional requirements

The control point must retrieve a list of rooms using the HomeAutomationGateway service and group the devices by room. It must also show the scenes in a room and support HomeAutomationGateway/RunScene to start a scene.

When a UPnP action results in a 'JobID' in the return arguments, it must use the HomeAutomationGateway/GetStatus action to show the user the job is in progress with a 'success' or 'fail' icon when it completes.

It must allow the user to operate the device when it's away from home by prompting the user for a username/password and secure gateway, which can stored if the user wishes, and changing the IP for the UPnP requests to the secure gateway and passing the username/password. No changes are required to the UPnP SOAP requests themselves to use the secure gateway; only the URL changes.

Personal tools