Everspring Sensors

From MiOS
(Difference between revisions)
Jump to: navigation, search
Line 7: Line 7:
 
== Inclusion:<br>  ==
 
== Inclusion:<br>  ==
  
To include an Everspring device with Vera, set your Vera to include mode, and then press ESC/[L] on the Everspring device 3 times within 1.5 seconds.&nbsp; The [L] icon on the Everspring device will flash.  
+
To include an Everspring device with Vera, set your Vera to include mode, and then press ESC/[L] on the Everspring device 3 times within 1.5 seconds.&nbsp; The [L] icon on the Everspring device will flash.&nbsp; Be patient.&nbsp; It can sometimes take a bit of time for Vera's UI to update with data from the sensor.&nbsp; It may help to reload Vera's UI and refresh your browser window after inclusion.<br>
 +
 
 +
 
  
 
Device File(s) known to work with Everspring Sensors:  
 
Device File(s) known to work with Everspring Sensors:  
Line 20: Line 22:
  
 
|  
 
|  
=== Device Files not Known to Work ===
+
=== Device Files not Known to Work/<br>Known not to Work<br> ===
  
 
|-
 
|-
Line 27: Line 29:
 
| <br>
 
| <br>
 
|-
 
|-
| ST815 Illumination Sensor with LCD <br>Vera (UI5) includes this sensor as a Generic IO device (D_GenericIO1.xml)  
+
| '''ST815 Illumination Sensor with LCD''' - Vera (UI5) includes the ST815 sensor as a Generic IO device (D_GenericIO1.xml).
| D_ComboDevice1.xml  
+
| D_ComboDevice1.xml - with the Combo Device file, the ST815's current value does not display in Vera's UI.<br>
 
|  
 
|  
D_GenericIO1.xml<br>D_LightSensor1.xml  
+
D_GenericIO1.xml (not known to work)<br>D_LightSensor1.xml (not known to work)<br>
  
 
|}
 
|}

Revision as of 14:56, 12 April 2013

Contents

Under Construction

This page is incomplete.

Everspring Sensors

Inclusion:

To include an Everspring device with Vera, set your Vera to include mode, and then press ESC/[L] on the Everspring device 3 times within 1.5 seconds.  The [L] icon on the Everspring device will flash.  Be patient.  It can sometimes take a bit of time for Vera's UI to update with data from the sensor.  It may help to reload Vera's UI and refresh your browser window after inclusion.


Device File(s) known to work with Everspring Sensors:

Device

Device File(s) Known to Work

Device Files not Known to Work/
Known not to Work

ST814 Temperature/Humidity Sensor

ST815 Illumination Sensor with LCD - Vera (UI5) includes the ST815 sensor as a Generic IO device (D_GenericIO1.xml). D_ComboDevice1.xml - with the Combo Device file, the ST815's current value does not display in Vera's UI.

D_GenericIO1.xml (not known to work)
D_LightSensor1.xml (not known to work)


Setting Device Parameters:

To set device parameters on Everspring devices:

  1. In Vera's UI, click on the wrench for the device and select the 'Device Options' tab (see below). 
  2. Select 'Add configuration settings' and add your first parameter (you can add only those parameters that you want to set). 
  3. After you have added the parameter values that you want to set within Vera, select SAVE, and the refresh your browser. 
  4. Wake up the Everspring device (for example, on the ST815 Illumination Sensor, press the ESC/[L] button 3 times within 1.5 seconds).  The device will stay awake for 10 seconds.
  5. Select 'Configure node right now' on the device's 'Settings' tab within Vera.



Example of Parameter Settings for ST815 Under UI5



Everspring ST815 Illumination Sensor with LCD

Parameter Function Size
(Byte)
Value Unit Default Set
(Factory Default)
Description
1 Basic Set Level 1 dec 0-99 Percent of Brightness (Dimmer Level) 99 (99) Set basic set value to be on (or set Lux Level)/off.
0: Disable
2 Lux Trigger - On Value 2 dec 30-1000 or 0 LUX 300 (0) Set Lux trigger-ON Value to be _Lux.
0: Clear Lux trigger-ON value
3 Lux Trigger - Off Value 2 dec 30-1000 or 0 LUX 500 (0) Set Lux trigger-OFF Value to be _Lux.
0: Clear Lux trigger-OFF value
4 Lux Trigger - Off (Timer Value) 2 dec 1-480 or 0 Minute 240 (0) Set Lux trigger-OFF Value to be _Lux.
0: Clear Lux trigger-OFF value
5 Auto Report (Time Interval) 2 dec 1-1439 or 0 Minutes 0 (0) Set auto report time interval to be _mins.
6 Auto Report (Lux Interval) 2 dec 30-1000 or 0 LUX 0 (0) Enable auto report.
0: Disable auto report.



Known Issues:

Personal tools