SmartSwitch

From MiOS
Revision as of 03:20, 15 June 2013 by A-lurker (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

These are the configurations settings available in the Device Options tab.


Param. #
Description Default Value
Allowed Values
90
Enables/disables parameters 91 and 92 below
1

0 - Disabled

1 - Enabled

91
Minimum change in wattage (in watts) for a report to be sent
50
1 - 65535
92
Minimum change in wattage percent (in percentage) for a report to be sent
10
1 - 255
101
Report 1
4 (4 = Watts)
4, 8
102
Report 2
8 (8 = KWH)
4, 8
111
The interval of sending Report 1 (in seconds)
1
1 - 65535
112
The interval of sending Report 2 (in seconds) 60
1 - 65535
















SmartSwitch device options.png

Personal tools