Danfoss Thermostat LC

From MiOS
Revision as of 22:10, 4 March 2014 by Ap15e (Talk | contribs)

Jump to: navigation, search

Please note that LC firmware revision 3.02 is not compatible with Z-Wave.


Contents

HW revisions

Part no. Firmware Z-Wave version Capabilities Z-Wave classes extra menu options Vera MiOS Photo Issues
014G0009 1.06 delay issueunreliable
014G0002, 014G0009 2.06 6,2,67,2,6 81,140,0,4,8,4,R,RS 67,70,114,117,128,129,132:2,134,143,145, No V2 1.5.408 206 image.jpg Dlc1.jpg Dlc2.jpg  ?
2.06 Lite 1.5.408 no issues
2.06 3 1.5.459 no issues
014G0012 2.50 Lite 1.5.408 no issues
014G0012 2.51 6,2,67,2,51 81,140,0,4,8,4,R,RS 67,70,114,117,128,129,132:2,134,143, 2 1.5.408 photo no issues
014G0012 2.5.3 Lite 1.5.408 no issues
014G0002 3.02 0x72, 0x91 only(?) not compatible
014G0013 1.00 6,3,67,1,0 83,156,0,4,8,4,R,B,RS 67,70,114,117,128,129,132:2,134,143 No 3 1.5.622, Z-Wave version 3.20 Danfoss LC SW1.00.jpg under test


Test results for Danfoss LC Z (014G0013, firmware version 1.00, wakeup interval 300 seconds; MiOS 1.5.622, Z-Wave version 3.20, Vera routing instead of Z-Wave)

Wakeup interval

KiZ.jpg WZ S.jpg WZ N.jpg B.jpg SZ.jpg

Excellent Wakeup performance. Non-equidistant points (B_Danfoss) due to manual operation.

Reaction time

Left vertical scale: CurrentSetpoint, CurrentTemperature

Right vertical scale: SetpointTarget

Temperature sensor near thermostat.

Danfoss SZ Reaction Time.jpg

Excellent reaction time (within one wakeup interval).

Power consumption

Using Sony batteries supplied with the thermostats.

DanfossBatteryLevel.jpg

Some abnormalities for KiZ_Danfoss (non-monotonically decreasing battery level, high drop on February, 27th).

Checking the wakeup interval

local danfoss_devices = { { 221, 'KiZ' }, 
                          { 218, 'B'   },
                          { 211, 'SZ'  },
                          { 107, 'WZS' },
                          {  94, 'WZN' }  }
 
function log_wakeup( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new )
 
 local s = ''
 
 for i = 1,#danfoss_devices
  do
 
   if danfoss_devices[ i ][ 1 ] == tonumber( lul_device ) 
    then
     s = danfoss_devices[ i ][ 2 ]
    end   
 
  end
 
 os.execute( 'logger -t Heizung Wakeup_' .. s )
 
end
 
 
for i = 1,#danfoss_devices
 do
  luup.variable_watch( 'log_wakeup', 'urn:micasaverde-com:serviceId:ZWaveDevice1', 'LastWakeup', danfoss_devices[ i ][ 1 ] )
 end

Synchronizing the Danfoss GUI device with temperature sensors

Danfoss CurrentTemperature.jpg

... using a TFA 30.3133 temperature sensor (ironically, MiOS doesn't support decidegrees for Z-Wave temperature sensors).


-- list of { temperature_sensor_device_id, { list of Danfoss_LC_device_id } }
 
devices_to_synchronize = { { 167, { 218      } },    -- B
                           { 162, { 221      } },    -- KiZ
                           { 169, { 211      } },    -- SZ
                           { 170, {  94, 107 } }  }  -- WZS, WZN
 
 
function synchronize_temp( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new )
 
 for i = 1,#devices_to_synchronize
  do
 
   if devices_to_synchronize[ i ][ 1 ] == tonumber( lul_device ) 
    then
 
     for j = 1,#devices_to_synchronize[ i ][ 2 ]
       do
        luup.variable_set( 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', lul_value_new, devices_to_synchronize[ i ][ 2 ][ j ] )
       end
 
    end
 
  end
 
end -- synchronize_temp
 
 
for i = 1,#devices_to_synchronize
 do
  luup.variable_watch( 'synchronize_temp', 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', devices_to_synchronize[ i ][ 1 ] )
 end