Everspring Sensors

From MiOS
Revision as of 13:57, 12 April 2013 by DaveL17 (Talk | contribs)

Jump to: navigation, search

Contents

Under Construction

Everspring Sensors

Inclusion:

Device File(s) known to work with Everspring Sensors:

Device

Device File(s)

ST814 Temperature/Humidity Sensor
ST815 Illumination Sensor with LCD D_ComboDevice1.xml



Setting Device Parameters:

Everspring ST815 Illumination Sensor with LCD

Parameter Function Size
(Byte)
Value Unit Default Set
(Factory Default)
Description
1 Basic Set Level 1 dec 0-99 Percent of Brightness (Dimmer Level) 99 (99) Set basic set value to be on (or set Lux Level)/off.
0: Disable
2 Lux Trigger - On Value 2 dec 30-1000 or 0 LUX 300 (0) Set Lux trigger-ON Value to be _Lux.
0: Clear Lux trigger-ON value
3 Lux Trigger - Off Value 2 dec 30-1000 or 0 LUX 500 (0) Set Lux trigger-OFF Value to be _Lux.
0: Clear Lux trigger-OFF value
4 Lux Trigger - Off (Timer Value) 2 dec 1-480 or 0 Minute 240 (0) Set Lux trigger-OFF Value to be _Lux.
0: Clear Lux trigger-OFF value
5 Auto Report (Time Interval) 2 dec 1-1439 or 0 Minutes 0 (0) Set auto report time interval to be _mins.
6 Auto Report (Lux Interval) 2 dec 30-1000 or 0 LUX 0 (0) Enable auto report.
0: Disable auto report.




Example of Parameter Settings for ST815 Under UI5



Known Issues: