Leviton Vizia Remote
From MiOS
To make Vera secondary to use the Leviton as primary you will need to follow these steps:
UI5
1) First you will need to change the Z-Wave firmware to 2.78:
Setup -> Z-Wave Settings ->Options -> uncheck the option 'Use Z-Wave version 3.20 instead of 2.78' and Save.
2) After you check that the version is 2.78 and not 3.20, you will need to change the _UNIT_NAME_ unit to be secondary, to do this go to:
Setup -> Z-Wave Settings -> Advanced -> click Go next to 'Controller shift'
3) Bring the Leviton controller near the _UNIT_NAME_ unit, less than 5 feet and on the _UNIT_NAME_ unit go to:
Setup -> Z-Wave Settings -> Advanced -> click Go next to 'Copy Z-Wave network from a master controller'
4) Then, on the remote controller you must go to:
'Menu - System Setup - Advanced - Yes - Network - Primary utils - Send primary data'
When the Vera unit is secondary, you will need to go to:
Setup -> Z-Wave Settings -> Options -> uncheck the options 'By default Vera should automatically configure devices' and 'Use Vera routing instead of Z-Wave (requires 4.5)'.
<span />
<span />
UI4
1) First you will need to change the Z-Wave firmware to 2.78:
Z-Wave device -> Options -> uncheck the option 'Use Z-Wave version 3.20 instead of 2.78' and Save
2) After you check that the version is 2.78 and not 3.20, you will need to change the _UNIT_NAME_ unit to be secondary, to do this go to:
Z-Wave device -> Advanced -> click Go next to 'Controller shift'3) Bring the Leviton controller near the _UNIT_NAME_ unit, less than 5 feet and on the _UNIT_NAME_ unit go to:
Z-Wave device -> Advanced -> click Go next to 'Copy Z-Wave network from a master controller'
4) Then, on the remote controller you must go to:
'Menu - System Setup - Advanced - Yes - Network - Primary utils - Send primary data'
When the Vera unit is secondary, you will need to go to:
Z-Wave device -> Options -> uncheck the options 'By default Vera should automatically configure devices' and 'Use Vera routing instead of Z-Wave (requires 4.5)'.