[edit] Yale Door lock

[edit] Adding/pairing the door lock into a Z-Wave network:

Please note that when pairing secure devices like door locks you will have to use the full power inclusion mode from the Dashboard.

UI4

I. Put Vera in include mode by using the full power inclusion mode:

1. Go to Vera's Dashboard

2. Click on Add/Remove devices in the upper left corner on the Dashboard

3. Click Next on Z-Wave

4. Scroll all the way down and select: Include, one node, with full power and timeout after 90 or 120 seconds and hit Go

II. Do the include procedure on the door lock:
1. Enter the 4-8 digit Master PIN code followed by the # key
2. Press 7 followed by the # key. (*This function appears only with network module installed)
3. Press 1 followed by the # key to include the door lock.

UI5

I. Put Vera in include mode by using the full power inclusion mode:

1. Go to Vera's Dashboard

2. Go to Devices -> Add devices

3. Click 'Add' next to 'Advanced Z-Wave devices'

4. Bellow 'Any type of Z-Wave device which you can bring close to Vera' select: Include, one node, with full power and timeout after 90 or 120 seconds and hit Go

II. Do the include procedure on the door lock:
1. Enter the 4-8 digit Master PIN code followed by the # key
2. Press 7 followed by the # key. (*This function appears only with network module installed)
3. Press 1 followed by the # key to include the door lock.


   
CAUTION: When joining a network your controller may or may not be aware of any previously saved user codes stored in the lock. It is recommended that all user codes be deleted from the lock prior to joining a network.


[edit] Deleting/Removing the door lock from a Z-Wave network:

UI4

1. Put Vera in exclude mode, by using the full power exclude mode (same as above, only instead of Include, select Exclude)

2. Enter the 4-8 digit Master PIN code followed by the # key

3. Press 7 followed by the # key. (*This function appears only with network module installed)

4. Press 3 followed by the # key to exclude the door lock.

UI5

I. Put Vera in exclude mode by using the full power exclusion mode:

1. Go to Vera's Dashboard

2. Go to Devices -> Add devices

3. Click 'Add' next to 'Advanced Z-Wave devices'

4. Bellow 'Any type of Z-Wave device which you can bring close to Vera' select: Exclude, one node, with full power and timeout after 90 or 120 seconds and hit Go

II. Do the include procedure on the door lock:
1. Enter the 4-8 digit Master PIN code followed by the # key
2. Press 7 followed by the # key. (*This function appears only with network module installed)
3. Press 1 followed by the # key to include the door lock.

[edit] Adding a pin code

To add a pin code, you will need to click on the 'wrench icon', click on the 'Pin codes' tab, check the check-box near 'Keep a copy of my pin codes', then enter the name 'New code name: ', after that enter the actual pin code next to '4-8 digit code: ', then click 'Set', and click the Save button in top right corner of the Dashboard.


[edit] References

Yale DB Touch Instructions