Danfoss Thermostat LC
From MiOS
(Difference between revisions)
(→HW revisions) |
(→HW revisions) |
||
Line 12: | Line 12: | ||
! Capabilities | ! Capabilities | ||
! Z-Wave classes | ! Z-Wave classes | ||
− | ! extra menu options | + | ! [http://forum.micasaverde.com/index.php/topic,12289.msg90659.html#msg90659 extra menu options] |
! Vera | ! Vera | ||
! MiOS | ! MiOS | ||
Line 34: | Line 34: | ||
| 81,140,0,4,8,4,R,RS | | 81,140,0,4,8,4,R,RS | ||
| 67,70,114,117,128,129,132:2,134,143,145, | | 67,70,114,117,128,129,132:2,134,143,145, | ||
− | | | + | | No |
| V2 | | V2 | ||
| 1.5.408 | | 1.5.408 |
Revision as of 21:05, 23 January 2013
Information applies to Danfoss Living Connect firmware revision 2.06 (and 2.50?) only. Firmware revision 3.02 is not compatible with Z-Wave.
Contents |
HW revisions
Part no. | Firmware | Z-Wave version | Capabilities | Z-Wave classes | extra menu options | Vera | MiOS | Photo | Issues |
---|---|---|---|---|---|---|---|---|---|
014G0009 | 1.06 | delay issueunreliable | |||||||
014G0002, 014G0009 | 2.06 | 6,2,67,2,6 | 81,140,0,4,8,4,R,RS | 67,70,114,117,128,129,132:2,134,143,145, | No | V2 | 1.5.408 | ? | |
2.06 | Lite | 1.5.408 | no issues | ||||||
2.06 | 3 | 1.5.459 | no issues | ||||||
014G0012 | 2.50 | Lite | 1.5.408 | no issues | |||||
2.51 | ? | ||||||||
014G0012 | 2.5.3 | Lite | 1.5.408 | no issues | |||||
014G0002 | 3.02 | 0x72, 0x91 only(?) | not compatible |
Checking the wakeup interval
local danfoss_devices = { { 221, 'KiZ' }, { 218, 'B' }, { 211, 'SZ' }, { 107, 'WZS' }, { 94, 'WZN' } } function log_wakeup( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new ) local s = '' for i = 1,#danfoss_devices do if danfoss_devices[ i ][ 1 ] == tonumber( lul_device ) then s = danfoss_devices[ i ][ 2 ] end end os.execute( 'logger -t Heizung Wakeup_' .. s ) end for i = 1,#danfoss_devices do luup.variable_watch( 'log_wakeup', 'urn:micasaverde-com:serviceId:ZWaveDevice1', 'LastWakeup', danfoss_devices[ i ][ 1 ] ) end
Synchronizing the Danfoss GUI device with temperature sensors
... using a TFA 30.3133 temperature sensor (ironically, MiOS doesn't support decidegrees for Z-Wave temperature sensors).
-- list of { temperature_sensor_device_id, { list of Danfoss_LC_device_id } } devices_to_synchronize = { { 167, { 218 } }, -- B { 162, { 221 } }, -- KiZ { 169, { 211 } }, -- SZ { 170, { 94, 107 } } } -- WZS, WZN function synchronize_temp( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new ) for i = 1,#devices_to_synchronize do if devices_to_synchronize[ i ][ 1 ] == tonumber( lul_device ) then for j = 1,#devices_to_synchronize[ i ][ 2 ] do luup.variable_set( 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', lul_value_new, devices_to_synchronize[ i ][ 2 ][ j ] ) end end end end -- synchronize_temp for i = 1,#devices_to_synchronize do luup.variable_watch( 'synchronize_temp', 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', devices_to_synchronize[ i ][ 1 ] ) end