Danfoss Thermostat LC
From MiOS
(Difference between revisions)
(→Checking the wakeup interval) |
(→HW revisions) |
||
| Line 34: | Line 34: | ||
| V2 | | V2 | ||
| 1.5.408 | | 1.5.408 | ||
| − | | | + | | [[File:206_image.jpg|100px]] |
| ? | | ? | ||
|- | |- | ||
Revision as of 12:12, 22 January 2013
Information applies to Danfoss Living Connect firmware revision 2.06 (and 2.50?) only. Firmware revision 3.02 is not compatible with Z-Wave.
Contents |
HW revisions
Checking the wakeup interval
local danfoss_devices = { { 221, 'KiZ' },
{ 218, 'B' },
{ 211, 'SZ' },
{ 107, 'WZS' },
{ 94, 'WZN' } }
function log_wakeup( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new )
local s = ''
for i = 1,#danfoss_devices
do
if danfoss_devices[ i ][ 1 ] == tonumber( lul_device )
then
s = danfoss_devices[ i ][ 2 ]
end
end
os.execute( 'logger -t Heizung Wakeup_' .. s )
end
for i = 1,#danfoss_devices
do
luup.variable_watch( 'log_wakeup', 'urn:micasaverde-com:serviceId:ZWaveDevice1', 'LastWakeup', danfoss_devices[ i ][ 1 ] )
endSynchronizing the Danfoss GUI device with temperature sensors
... using a TFA 30.3133 temperature sensor (ironically, MiOS doesn't support decidegrees for Z-Wave temperature sensors).
-- list of { temperature_sensor_device_id, { list of Danfoss_LC_device_id } }
devices_to_synchronize = { { 167, { 218 } }, -- B
{ 162, { 221 } }, -- KiZ
{ 169, { 211 } }, -- SZ
{ 170, { 94, 107 } } } -- WZS, WZN
function synchronize_temp( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new )
for i = 1,#devices_to_synchronize
do
if devices_to_synchronize[ i ][ 1 ] == tonumber( lul_device )
then
for j = 1,#devices_to_synchronize[ i ][ 2 ]
do
luup.variable_set( 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', lul_value_new, devices_to_synchronize[ i ][ 2 ][ j ] )
end
end
end
end -- synchronize_temp
for i = 1,#devices_to_synchronize
do
luup.variable_watch( 'synchronize_temp', 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', devices_to_synchronize[ i ][ 1 ] )
end