SmartSwitch
From MiOS
(Difference between revisions)
m |
m |
||
Line 10: | Line 10: | ||
|- | |- | ||
| 90<br> | | 90<br> | ||
− | | Enables/disables | + | | Enables/disables parameters 91 and 92 below<br> |
| 1<br> | | 1<br> | ||
| | | |
Revision as of 15:16, 8 February 2012
These are the configurations settings available in the Device Options tab.
Param. # |
Description | Default Value |
Allowed Values |
---|---|---|---|
90 |
Enables/disables parameters 91 and 92 below |
1 |
0 - Disabled 1 - Enabled |
91 |
Minimum change in wattage (in watts) for a report to be sent |
50 |
1 - 65535 |
92 |
Minimum change in wattage percent (in percentage) for a report to be sent |
10 |
1 - 255 |
101 |
Report 1 |
4 (4 = Watts) |
4, 8 |
102 |
Report 2 |
8 (8 = KWH) |
4, 8 |
111 |
The interval of sending Report 1 (in seconds) |
1 |
1 - 65535 |
112 |
The interval of sending Report 2 (in seconds) | 60 |
1 - 65535 |