Everspring Sensors
Line 125: | Line 125: | ||
<br> | <br> | ||
− | == Known Issues: == | + | == Known Issues: == |
+ | |||
+ | There are some known issues with using Everspring devices with Vera (discuss polling, auto reports, etc.) |
Revision as of 15:04, 12 April 2013
Contents |
Under Construction
This page is incomplete.
Everspring Sensors
Inclusion:
To include an Everspring device with Vera, set your Vera to include mode, and then press ESC/[L] on the Everspring device 3 times within 1.5 seconds. The [L] icon on the Everspring device will flash. Be patient. It can sometimes take a bit of time for Vera's UI to update with data from the sensor. It may help to reload Vera's UI and refresh your browser window after inclusion.
Device File(s) known to work with Everspring Sensors:
Device |
Device File(s) Known to Work
|
Device Files not Known to Work/
|
ST814 Temperature/Humidity Sensor - |
|
|
ST815 Illumination Sensor with LCD - Vera (UI5) includes the ST815 sensor as a Generic IO device (D_GenericIO1.xml). | D_ComboDevice1.xml - the ST815's current value does not display in Vera's UI. |
D_GenericIO1.xml (not known to work) |
Setting Device Parameters:
To set device parameters on Everspring devices:
- In Vera's UI, click on the wrench for the device and select the 'Device Options' tab (see below).
- Select 'Add configuration settings' and add your first parameter (you can add only those parameters that you want to set).
- After you have added the parameter values that you want to set within Vera, select SAVE, and the refresh your browser.
- Wake up the Everspring device (for example, on the ST815 Illumination Sensor, press the ESC/[L] button 3 times within 1.5 seconds). The device will stay awake for 10 seconds.
- Select 'Configure node right now' on the device's 'Settings' tab within Vera.
Everspring ST815 Illumination Sensor with LCD | ||||||
---|---|---|---|---|---|---|
Parameter | Function | Size (Byte) |
Value | Unit | Default Set (Factory Default) |
Description |
1 | Basic Set Level | 1 dec | 0-99 | Percent of Brightness (Dimmer Level) | 99 (99) | Set basic set value to be on (or set Lux Level)/off. 0: Disable |
2 | Lux Trigger - On Value | 2 dec | 30-1000 or 0 | LUX | 300 (0) | Set Lux trigger-ON Value to be _Lux. 0: Clear Lux trigger-ON value |
3 | Lux Trigger - Off Value | 2 dec | 30-1000 or 0 | LUX | 500 (0) | Set Lux trigger-OFF Value to be _Lux. 0: Clear Lux trigger-OFF value |
4 | Lux Trigger - Off (Timer Value) | 2 dec | 1-480 or 0 | Minute | 240 (0) | Set Lux trigger-OFF Value to be _Lux. 0: Clear Lux trigger-OFF value |
5 | Auto Report (Time Interval) | 2 dec | 1-1439 or 0 | Minutes | 0 (0) | Set auto report time interval to be _mins. |
6 | Auto Report (Lux Interval) | 2 dec | 30-1000 or 0 | LUX | 0 (0) | Enable auto report. 0: Disable auto report. |
Known Issues:
There are some known issues with using Everspring devices with Vera (discuss polling, auto reports, etc.)