+ | To include an Everspring device with Vera, set your Vera to include mode, and then press ESC/[L] on the Everspring device 3 times within 1.5 seconds. The [L] icon on the Everspring device will flash. | ||
Device File(s) known to work with Everspring Sensors: | Device File(s) known to work with Everspring Sensors: | ||
− | {| width=" | + | {| width="100%" cellspacing="1" cellpadding="1" border="1" |
|- | |- | ||
| | | | ||
Line 13: | Line 15: | ||
| | | | ||
− | === Device File(s) | + | === Device File(s) Known to Work<br> === |
+ | |||
+ | | | ||
+ | === Device Files not Known to Work === | ||
|- | |- | ||
| ST814 Temperature/Humidity Sensor | | ST814 Temperature/Humidity Sensor | ||
+ | | | ||
| | | | ||
|- | |- | ||
− | | ST815 Illumination Sensor with LCD | + | | ST815 Illumination Sensor with LCD <br>Vera (UI5) includes this sensor as a Generic IO device (D_GenericIO1.xml) |
− | | D_ComboDevice1.xml | + | | D_ComboDevice1.xml |
+ | | D_GenericIO1.xml<br>D_LightSensor1.xml | ||
|} | |} | ||
Revision as of 14:49, 12 April 2013
Contents |
Under Construction
Everspring Sensors
Inclusion:
To include an Everspring device with Vera, set your Vera to include mode, and then press ESC/[L] on the Everspring device 3 times within 1.5 seconds. The [L] icon on the Everspring device will flash.
Device File(s) known to work with Everspring Sensors:
Device |
Device File(s) Known to Work
|
Device Files not Known to Work |
ST814 Temperature/Humidity Sensor | ||
ST815 Illumination Sensor with LCD Vera (UI5) includes this sensor as a Generic IO device (D_GenericIO1.xml) |
D_ComboDevice1.xml | D_GenericIO1.xml D_LightSensor1.xml |
Setting Device Parameters:
To set device parameters on Everspring devices:
- In Vera's UI, click on the wrench for the device and select the 'Device Options' tab (see below).
- Select 'Add configuration settings' and add your first parameter (you can add only those parameters that you want to set).
- After you have added the parameter values that you want to set within Vera, select SAVE, and the refresh your browser.
- Wake up the Everspring device (for example, on the ST815 Illumination Sensor, press the ESC/[L] button 3 times within 1.5 seconds). The device will stay awake for 10 seconds.
- Select 'Configure node right now' on the device's 'Settings' tab within Vera.
Everspring ST815 Illumination Sensor with LCD | ||||||
---|---|---|---|---|---|---|
Parameter | Function | Size (Byte) |
Value | Unit | Default Set (Factory Default) |
Description |
1 | Basic Set Level | 1 dec | 0-99 | Percent of Brightness (Dimmer Level) | 99 (99) | Set basic set value to be on (or set Lux Level)/off. 0: Disable |
2 | Lux Trigger - On Value | 2 dec | 30-1000 or 0 | LUX | 300 (0) | Set Lux trigger-ON Value to be _Lux. 0: Clear Lux trigger-ON value |
3 | Lux Trigger - Off Value | 2 dec | 30-1000 or 0 | LUX | 500 (0) | Set Lux trigger-OFF Value to be _Lux. 0: Clear Lux trigger-OFF value |
4 | Lux Trigger - Off (Timer Value) | 2 dec | 1-480 or 0 | Minute | 240 (0) | Set Lux trigger-OFF Value to be _Lux. 0: Clear Lux trigger-OFF value |
5 | Auto Report (Time Interval) | 2 dec | 1-1439 or 0 | Minutes | 0 (0) | Set auto report time interval to be _mins. |
6 | Auto Report (Lux Interval) | 2 dec | 30-1000 or 0 | LUX | 0 (0) | Enable auto report. 0: Disable auto report. |