Danfoss Thermostat LC
From MiOS
(Difference between revisions)
(→HW revisions) |
m (→HW revisions) |
||
| Line 73: | Line 73: | ||
| [http://forum.micasaverde.com/index.php/topic,12289.msg99321.html#msg99321 no issues] | | [http://forum.micasaverde.com/index.php/topic,12289.msg99321.html#msg99321 no issues] | ||
|- | |- | ||
| − | | | + | | 014G0012 |
| 2.51 | | 2.51 | ||
| + | | 6,2,67,2,51 | ||
| + | | 81,140,0,4,8,4,R,RS | ||
| + | | 67,70,114,117,128,129,132:2,134,143, | ||
| | | | ||
| − | | | + | | 2 |
| − | | | + | | 1.5.408 |
| − | | | + | | [http://forum.micasaverde.com/index.php?action=dlattach;topic=12289.0;attach=9066 photo] |
| − | | | + | | [http://forum.micasaverde.com/index.php/topic,12289.msg102315.html#msg102315 no issues] |
| − | + | ||
| − | + | ||
| − | + | ||
|- | |- | ||
| 014G0012 | | 014G0012 | ||
Revision as of 00:16, 14 February 2013
Information applies to Danfoss Living Connect firmware revision 2.06 (and 2.50?) only. Firmware revision 3.02 is not compatible with Z-Wave.
Contents |
HW revisions
| Part no. | Firmware | Z-Wave version | Capabilities | Z-Wave classes | extra menu options | Vera | MiOS | Photo | Issues |
|---|---|---|---|---|---|---|---|---|---|
| 014G0009 | 1.06 | delay issueunreliable | |||||||
| 014G0002, 014G0009 | 2.06 | 6,2,67,2,6 | 81,140,0,4,8,4,R,RS | 67,70,114,117,128,129,132:2,134,143,145, | No | V2 | 1.5.408 | |
? |
| 2.06 | Lite | 1.5.408 | no issues | ||||||
| 2.06 | 3 | 1.5.459 | no issues | ||||||
| 014G0012 | 2.50 | Lite | 1.5.408 | no issues | |||||
| 014G0012 | 2.51 | 6,2,67,2,51 | 81,140,0,4,8,4,R,RS | 67,70,114,117,128,129,132:2,134,143, | 2 | 1.5.408 | photo | no issues | |
| 014G0012 | 2.5.3 | Lite | 1.5.408 | no issues | |||||
| 014G0002 | 3.02 | 0x72, 0x91 only(?) | not compatible |
Checking the wakeup interval
local danfoss_devices = { { 221, 'KiZ' },
{ 218, 'B' },
{ 211, 'SZ' },
{ 107, 'WZS' },
{ 94, 'WZN' } }
function log_wakeup( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new )
local s = ''
for i = 1,#danfoss_devices
do
if danfoss_devices[ i ][ 1 ] == tonumber( lul_device )
then
s = danfoss_devices[ i ][ 2 ]
end
end
os.execute( 'logger -t Heizung Wakeup_' .. s )
end
for i = 1,#danfoss_devices
do
luup.variable_watch( 'log_wakeup', 'urn:micasaverde-com:serviceId:ZWaveDevice1', 'LastWakeup', danfoss_devices[ i ][ 1 ] )
endSynchronizing the Danfoss GUI device with temperature sensors
... using a TFA 30.3133 temperature sensor (ironically, MiOS doesn't support decidegrees for Z-Wave temperature sensors).
-- list of { temperature_sensor_device_id, { list of Danfoss_LC_device_id } }
devices_to_synchronize = { { 167, { 218 } }, -- B
{ 162, { 221 } }, -- KiZ
{ 169, { 211 } }, -- SZ
{ 170, { 94, 107 } } } -- WZS, WZN
function synchronize_temp( lul_device, lul_service, lul_variable, lul_value_old, lul_value_new )
for i = 1,#devices_to_synchronize
do
if devices_to_synchronize[ i ][ 1 ] == tonumber( lul_device )
then
for j = 1,#devices_to_synchronize[ i ][ 2 ]
do
luup.variable_set( 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', lul_value_new, devices_to_synchronize[ i ][ 2 ][ j ] )
end
end
end
end -- synchronize_temp
for i = 1,#devices_to_synchronize
do
luup.variable_watch( 'synchronize_temp', 'urn:upnp-org:serviceId:TemperatureSensor1', 'CurrentTemperature', devices_to_synchronize[ i ][ 1 ] )
end