Supported Hardware

From MiOS
(Difference between revisions)
Jump to: navigation, search
(Door Locks)
(add easy-light Relais)
 
(206 intermediate revisions by 34 users not shown)
Line 1: Line 1:
Note: There is a separate page for Z-Wave Handheld remote controls, Z-Wave gateways, and Z-Wave Scene Controllers: [[ZWave_Add_Controller|click here]]  There is also a separate page for IP cameras: [[IP_Cameras|click here]]
+
This is a page for Supported Z-Wave devices.
  
In general, any device with the Z-Wave logo should work with Vera.  A list of tested Z-Wave devices is below, with specific notes for each type of device.  This is a wiki, so feel free to add to the page.
+
Alternative hardware pages exist for  
  
== Hardware Reported to Work ==
+
*[[ZWave Add Controller|Z-Wave Handheld Remote Controls, Gateways and Scene Controllers]]
 +
*[[IP Cameras|IP Enabled Cameras]]
 +
*[[Insteon Supported Hardware|Insteon/X10 devices]]
 +
*USB, or USB-Serial, [[Serial Supported Hardware|Interface devices]]
  
* We strongly encourage users to list any and all products they tested and installed.
+
In general, any device with the Z-Wave logo should work with Vera. A list of tested Z-Wave devices is below, with specific notes for each type of device. This is a wiki, so feel free to add to the page. To learn about Z-Wave routing and fixing routing problems see: [[Heal Network]]
* If a product works but you did not like it, please list it anyway. It may be the only product available to some users.
+
  
 +
== Hardware Reported to Work  ==
 +
 +
*We strongly encourage users to list any and all products they tested and installed.
 +
*If a product works but you did not like it, please list it anyway. It may be the only product available to some users.
 +
 +
<br>
  
 
----
 
----
'''IMPORTANT!   The devices listed here have been added by installers,technicians and users like yourself. Results may vary upon installations. MiCasaVerde does not guarantee operation and compatibility with your installation. The listed devices were found to work with their specific installation. Mixing different series and brands of equipment is not guaranteed in any way to work with other series and brands. It is very likely that users have not fully tested all features of the devices, so it is possible that a device listed here as compatible, will not prove compatible with your hardware. If you are editing this wiki DO NOT REMOVE a listed working device if it hasn't worked for you. Seek help to get the device to work under your individual circumstance. If you are adding to this wiki, please provide links to data for the device and add any tips you feel may benefit someone wanting to implement the device into an installation'''
+
 
 +
'''IMPORTANT! The devices listed here have been added by installers, technicians and users like yourself. Results may vary upon installations. MiCasaVerde does not guarantee operation and compatibility with your installation. The listed devices were found to work with their specific installation. Mixing different series and brands of equipment is not guaranteed in any way to work with other series and brands. It is very likely that users have not fully tested all features of the devices, so it is possible that a device listed here as compatible, will not prove compatible with your hardware. If you are editing this wiki DO NOT REMOVE a listed working device if it hasn't worked for you. Seek help to get the device to work under your individual circumstance. If you are adding to this wiki, please provide links to data for the device and add any tips you feel may benefit someone wanting to implement the device into an installation.'''  
 +
 
 
----
 
----
  
 +
<br>
  
=== '''Lighting Devices''' ===
+
=== '''Lighting Devices''' ===
  
{| border="1" cellpadding="2"
+
{| class="wikitable"
! Manufacturer !! Device Type !! Model no. !! Version !! Date Purchased !! Location (indoor/outdoor) !! Specs !! Product Review !! Added by User !! Notes
+
 
|-
 
|-
|| Leviton || Dimmer Switch || VRM10-1LX || 1 || Nov 2008 || Indoor || [http://shop.micasaverde.com/index.php?main_page=product_info&cPath=104&products_id=170 Link] || [http://www.amazon.com/review/product/B000ZKM7I8/ref=dp_top_cm_cr_acr_txt?_encoding=UTF8&showViewpoints=1 Link] || [http://forum.micasaverde.com/index.php?action=profile;u=65 mark-hc] ||This is a high quality dimmer geared towards high-end installations
+
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added by User
 +
! Notes
 +
|-
 +
| ACT
 +
| 2-way Dimmer Switch
 +
| ZDW120
 +
| <br>
 +
| Nov 2008
 +
| Indoor
 +
| [http://store.homeseer.com/store/ZDW120---Z-Wave-600-Watt-2-Wire-Dimmer-ACT-HomePro-P17C64.aspx Link]
 +
| [http://store.homeseer.com/store/ZDW120---Z-Wave-600-Watt-2-Wire-Dimmer-ACT-HomePro-P17C64.aspx Link]
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]
 +
| Works well, easy to install, LED is a very bright blue....can be programmed to be off when the light is off or on. "series 200" model supports Group Associations 2 &amp; 3. (The older "series 100" supported Groups 1-4, but is no longer available.)
 +
|-
 +
| ACT
 +
| 3-way Dimmer Switch  
 +
| ZDW103
 +
| <br>
 +
| Nov 2008
 +
| Indoor
 +
| [http://store.homeseer.com/store/ZDW103---Z-Wave-500-Watt-3-way-Dimmer-ACT-HomePro-P19C64.aspx Link]
 +
| [http://store.homeseer.com/store/ZDW103---Z-Wave-500-Watt-3-way-Dimmer-ACT-HomePro-P19C64.aspx Link]
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]
 +
| Works well, can be tricky to install due to the different combination of 3 way circuits, LED is a very bright blue....can be programmed to be off when the light is off or on.
 +
|-
 +
| ACT
 +
| 2-wire Dimmer Switch
 +
| ZDW232
 +
| <br>
 +
| Jul 2010
 +
| Indoor
 +
| [http://www.zwave4u.com/products/en/Switches-and-Dimmers/HomePro-Single-Wall-Dimmer-2-wire.html Link]
 +
| [http://www.zwave4u.com/products/en/Switches-and-Dimmers/HomePro-Single-Wall-Dimmer-2-wire.html Link]
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=5198 Newb]
 +
| Wall-mount, 230v, 500W, 2-Wire (no neutral), works well. Can be programmed to be off when the light is off or on.
 +
|-
 +
| ACT
 +
| 2-way Relay Switch
 +
| ZRW113
 +
| <br>
 +
| Nov 2008
 +
| Indoor
 +
| [http://store.homeseer.com/store/ZRW113---Z-Wave-20-Amp-3-way-ISO-Relay-ACT-HomePro-P491C63.aspx Link]
 +
| [http://store.homeseer.com/store/ZRW113---Z-Wave-20-Amp-3-way-ISO-Relay-ACT-HomePro-P491C63.aspx Link]
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]
 +
| Controls Florescent Lamps very well! No humming at all.
 +
|-
 +
| ACT
 +
| Companion Switch
 +
| AS101
 +
| <br>
 +
| Nov 2008
 +
| Indoor
 +
| [http://store.homeseer.com/store/AS101---Z-Wave-3-Way-Companion-Switch-ACT-HomePro-P10C63.aspx Link]
 +
| [http://store.homeseer.com/store/AS101---Z-Wave-3-Way-Companion-Switch-ACT-HomePro-P10C63.aspx Link]
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]
 +
| Works well, can be tricky to install due to the different combination of 3 way circuits, The trick here is to install this device where the power comes in.
 +
|-
 +
| ACT<br>
 +
| 3-way Dimmer Switch, 2 rocker<br>
 +
| ZDM230<br>
 +
| 1.1<br>
 +
| Aug 2009<br>
 +
| Indoor<br>
 +
| [http://www.act-solutions.com/HomePro/pdfs/HomePro/Specs/ZDM230_spec.pdf Link]<br>
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=3015 TedStriker]<br>
 +
| Dimmer, Wall-mount, 230v, 500W,<br>3-way, 3 Wire, 2 rocker<br>
 +
|-
 +
| ACT
 +
| 3-way Relay Switch, 2 rocker
 +
| ZRM230<br>
 +
| 1.1<br>
 +
| Aug 2009<br>
 +
| Indoor<br>
 +
| [http://www.act-solutions.com/HomePro/pdfs/HomePro/Specs/ZRM230_spec.pdf Link]<br>
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=3015 TedStriker]<br>
 +
| <font size="2">Relay, Wall-mount, 230v, 6A,<br> 3-way, 3 Wire, 2 rocker - '''Status polling does not work with Vera'''<br></font>
 +
|-
 +
| Cooper
 +
| Accessory (3-way slave)
 +
| <br>
 +
| <br>
 +
| <br>
 +
| Indoor
 +
| <br>
 +
| <br>
 +
| <br>
 +
| See [[Cooper Accessory Slave]]
 +
|-
 +
| Düwi
 +
| 2 wire dimmer
 +
| <br>
 +
| <br>
 +
| July 2011
 +
| Indoor
 +
| <br>
 +
| <br>
 +
| intveltr
 +
| In-wall dimmer.
 +
|-
 +
| Düwi
 +
| 3 wire switch
 +
| 05431
 +
| <br>
 +
| July 2011
 +
| Indoor
 +
| <br>
 +
| <br>
 +
| intveltr
 +
| In-wall switch.
 +
|-
 +
| Düwi
 +
| 3 wire switch
 +
| 06431
 +
| <br>
 +
| July 2011
 +
| Indoor
 +
| <br>
 +
| <br>
 +
| intveltr
 +
| The newer in-wall Düwi switch (also designated Düwi.me), marked with a green sticker on the housing. This switch supports status push.
 +
|-
 +
| Fibar
 +
| 3 wire double switch
 +
| FGS221
 +
| <br>
 +
| Oct 2011
 +
| Indoor
 +
| <br>
 +
| <br>
 +
| intveltr
 +
| This device is designed to use (and be mounted behind) existing light switches. Supports status push. Also available: single switch, dimmer, blind control.
 +
|-
 +
| GE/Jasco
 +
| Lamp Module w/Dimmer
 +
| 45602
 +
| &nbsp;
 +
| 7/2011
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| Works with most incandescent bulbs.
 +
|-
 +
| GE/Jasco
 +
| Fluorescent Light &amp; Appliance Module
 +
| 45603
 +
| &nbsp;
 +
| 7/2011
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| Works with small appliances, incandescent, fluorescent and LED bulbs.
 +
|-
 +
| GE/Jasco
 +
| Outdoor Switch Module
 +
| 45604
 +
| &nbsp;
 +
| 7/2011
 +
| Outdoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| Works with small appliances, incandescent, fluorescent and LED bulbs.
 +
|-
 +
| GE/Jasco
 +
| On/Off/Dim Dimmer Switch
 +
| 45606
 +
| &nbsp;
 +
| 2/2011
 +
| Indoor
 +
| [http://www.jascoproducts.com/support/manual-downloads/applications/DocumentLibraryManager/upload/45606-Manual-Eng.pdf Link] [http://www.jascoproducts.com/products/pc/GE-Z-Wave-Wireless-Lighting-Control-Dimmer-Switch-63p555.htm Link]
 +
| &nbsp;
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=64 Anthonyris]
 +
| Discontinued, See 45612. Requires neutral lead. Works fine with most bulbs. With Philips AmbientLED, flickers at &gt;95% brightness. Supports beaming. Flickers at low-levels with dimmable LED.
 +
|-
 +
| GE/Jasco
 +
| Dimmer Switch
 +
| 45607
 +
| &nbsp;
 +
| &nbsp;
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
|-
 +
| GE/Jasco
 +
| On/Off Switch
 +
| 45609
 +
| &nbsp;
 +
| 7/2011
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
|-
 +
| GE/Jasco
 +
| Auxiliary Switch
 +
| 45610
 +
| &nbsp;
 +
| 7/2011
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| No zwave function; for 3 and 4-way switching kits
 +
|-
 +
| GE/Jasco
 +
| 2-way Rocker Dimmer
 +
| 45612
 +
| &nbsp;
 +
| 2/2012
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| No neutral required; replaces 45606
 +
|-
 +
| GE/Jasco
 +
| 3-way Dimmer Kit
 +
| 45613
 +
| &nbsp;
 +
| &nbsp;
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| Possible error in 45613 manual diagrams, see 45610 diagrams
 +
|-
 +
| GE/Jasco
 +
| 3-way Switch Kit
 +
| 45614
 +
| &nbsp;
 +
| 7/2011
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
|-
 +
| Innovus
 +
| Relay Switch Adapter
 +
| RAone SmartPower
 +
| &nbsp;
 +
| Aug 2009
 +
| Indoor
 +
| [http://www.innovus.eu/fileadmin/user_upload/manual/z-wave/smartpower_zw_tech_doc.pdf Link]
 +
| &nbsp;
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=3015 TedStriker]
 +
| Works very well + it has a build in powermeter which works perfect with Vera
 +
|-
 +
| Innovus
 +
| Dimmer Switch Adapter
 +
| RAone SmartDimmer
 +
| &nbsp;
 +
| Aug 2009
 +
| Indoor
 +
| [http://www.innovus.eu/fileadmin/user_upload/manual/z-wave/smartdimmer-00110001-tech.pdf Link]
 +
| &nbsp;
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=3015 TedStriker]
 +
| Works very well + it has a build in powermeter which works perfect with Vera
 +
|-
 +
| Intermatic
 +
| Lamp Module
 +
| HA03C
 +
| &nbsp;
 +
| Sept 2010
 +
| Indoor
 +
| [http://www.homesettings.com/products/modules/ha03.aspx Link]
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=5852 JonnyO]
 +
| Easy to Instal, supports dimming
 +
|-
 +
| Intermatic
 +
| Screw-in Lamp Module
 +
| HA05C
 +
| <br>
 +
| Nov 2008  
 +
| Indoor/Outdoor
 +
| [http://store.homeseer.com/store/HA05C---Z-Wave-IndoorOutdoor-Screw-in-Module-Intermatic-HomeSettings-P1C62.aspx Link]
 +
| [http://store.homeseer.com/store/HA05C---Z-Wave-IndoorOutdoor-Screw-in-Module-Intermatic-HomeSettings-P1C62.aspx Link]
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]
 +
| Easy install, easy to pair with Vera!
 +
|-
 +
| Intermatic
 +
| 300 watt dimmer
 +
| HA06
 +
| <br>
 +
| July 2007
 +
| Indoor  
 +
| [http://www.homesettings.com/products/modules/ha06.aspx Link]
 +
| <br>
 +
| <br>
 +
| Affordable Dimmer Switch. incandescent/halogen only. Loads for 300 watts or less no neutral required. Great for dimming one bulb.
 +
|-
 +
| Intermatic
 +
| 3-way Switch
 +
| HA18
 +
| <br>
 +
| Dec 2008
 +
| Indoor
 +
| [http://www.homesettings.com/products/new%20products/ha18.aspx Link]
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=66 Kozanator]
 +
| Affordable 3-way Switch
 +
|-
 +
| Intermatic
 +
| 3-way Dimmer Switch
 +
| HA20
 +
| <br>
 +
| Nov 2008
 +
| Indoor
 +
| [http://www.homesettings.com/products/new%20products/ha20.aspx Link]
 +
| [http://www.smarthome-products.com/p-460-intermatic-homesettings-ha20c-3-way-in-wall-switch-dimmer.aspx Link]
 +
| <br>
 +
| Affordable 3-way 600W dimmer
 +
|-
 +
| Leviton
 +
| Dimmer Switch
 +
| VRI06-1LX
 +
| &nbsp;
 +
| Aug 2009
 +
| Indoor
 +
| [http://www.leviton.com/OA_HTML/ibeCCtpItmDspRte.jsp?item=305784&section=25501 Link]
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=2618 guessed]
 +
| Works well
 +
|-
 +
| Leviton
 +
| 4-Scene Controller with Switch
 +
| VRCS4-MRX
 +
| 7,2,67,0,2
 +
| Aug 2009
 +
| Indoor
 +
| [http://www.leviton.com/OA_HTML/ibeCCtpItmDspRte.jsp?item=433270&section=28563 Link]
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=2618 guessed]
 +
| Works well, pair as per [http://wiki.micasaverde.com/index.php/Leviton_Scene_Controller Leviton 4-Scene Controller], then again holding "2" and "4" to pair the Switch ("Load") itself.
 +
|-
 +
| Leviton
 +
| Dimmer Switch
 +
| VRM10-1LX
 +
| 1
 +
| Nov 2008
 +
| Indoor
 +
| [http://shop.micasaverde.com/index.php?main_page=product_info&cPath=104&products_id=170 Link]  
 +
| [http://www.amazon.com/review/product/B000ZKM7I8/ref=dp_top_cm_cr_acr_txt?_encoding=UTF8&showViewpoints=1 Link]  
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=65 mark-hc]  
 +
| This is a high quality dimmer geared towards high-end installations
 +
|-
 +
| Leviton
 +
| Scene capable 3-way switch (non-dimming)
 +
| VRS15-1L
 +
| &nbsp;
 +
| May 2011
 +
| Indoor
 +
| [http://www.leviton.com/OA_HTML/ibeCCtpItmDspRte.jsp?item=305791&section=25502&minisite=10026 Link]
 +
| <br>
 +
| DaveL17
 +
| (Coordinating Remote??)
 +
|-
 +
| Leviton
 +
| Scene capable 3-way switch (non-dimming)
 +
| VRS15-1LX
 +
| &nbsp;
 +
| Oct 2011
 +
| Indoor
 +
| [http://www.leviton.com/OA_HTML/ibeCCtpItmDspRte.jsp?item=305791&section=25502&minisite=10026 Link]
 +
| <br>
 +
| DaveL17
 +
| Works well. Pair normally. Can also be used in single pole applications. [Note: white, ivory, [[Almond]].]
 +
|-
 +
| Leviton
 +
| Scene capable 3-way switch (non-dimming)
 +
| VRS15-1LZ
 +
| &nbsp;
 +
| &nbsp;
 +
| Indoor
 +
| [http://www.leviton.com/OA_HTML/ibeCCtpItmDspRte.jsp?item=305791&section=25502&minisite=10026 Link]
 +
| <br>
 +
| DaveL17
 +
| Works well. Pair normally. Can also be used in single pole applications. [Note: white, ivory, [[Light almond]].]
 +
|-
 +
| Merten
 +
| Radio sensor cover for dimmer inserts
 +
| 5026xx, 5036xx, 5046xx
 +
| 6,2,7,1,5
 +
| Apr 2009
 +
| Indoor
 +
| [http://www.merten.de/download/DL_doku/V5026_581_01_web.pdf Link]
 +
| &nbsp;
 +
| Ap15e
 +
| Works well
 +
|-
 +
| Merten
 +
| Radio sensor cover for dimmer inserts
 +
| 5026xx, 5036xx, 5046xx
 +
| 6,2,7,1,5
 +
| Apr 2009
 +
| Indoor
 +
| [http://www.merten.de/download/DL_doku/V5026_581_01_web.pdf Link]
 +
| &nbsp;
 +
| Ap15e
 +
| Works well
 +
|-
 +
| Merten
 +
| Single Radio flush-mounted receiver
 +
| 507001
 +
| 6,2,27,2,2
 +
| Apr 2009
 +
| Indoor
 +
| [http://www.merten.de/download/DL_doku/V5070_581_01_web.pdf Link]
 +
| &nbsp;
 +
| Ap15e
 +
| Works well
 +
|-
 +
| Merten
 +
| switch, flush-mounted
 +
| 507501, 507601
 +
| &nbsp;
 +
| &nbsp;
 +
| Indoor
 +
| [http://www.merten.de/download/DL_doku/V5075_581_00_web.pdf Link]
 +
| &nbsp;
 +
| Ap15e
 +
| Works well (according to [http://forum.micasaverde.com/index.php?topic=276.15 Link])
 +
|-
 +
| Merten
 +
| 1-gang universal dimmer, flush-mounted
 +
| 507900
 +
| &nbsp;
 +
| &nbsp;
 +
| Indoor
 +
| [http://www.merten.de/download/DL_doku/V5079_581_01_web.pdf Link]
 +
| &nbsp;
 +
| Ap15e
 +
| Works well (according to [http://forum.micasaverde.com/index.php?topic=276.15 Link])
 +
|-
 +
| Monster
 +
| 4-Scene Controller with Switch
 +
| IWC600
 +
| <br>
 +
| Dec 2011
 +
| Indoor
 +
| [http://www.leviton.com/OA_HTML/ibeCCtpItmDspRte.jsp?item=433270&section=28563 Link]
 +
| <br>
 +
| <br>
 +
| This is the same as the Leviton scene controller. Follow these instructions: [http://wiki.micasaverde.com/index.php/Leviton_Scene_Controller Leviton 4-Scene Controller]
 +
|-
 +
| Mvava
 +
| Touch Based Light Switch (EU)
 +
| MVA1102
 +
| &nbsp;
 +
| Feb 2013
 +
| Indoor
 +
| [[File:Mvava 2Gang-Touch.jpg|thumb|center|x160px|photo]]
 +
| &nbsp;
 +
| [[User:Nullx8|nullx8]]
 +
| available in 1,2 and 3 Gang,<br />no Immediate Update of status changes<br />requires Neutral wire,<br /><br />nice and good quality finishing,<br />Switched load 2x1100VA<br />[http://www.mvava.com/ website for contacts, currently no z-wave product info] <br />company has not much knowledge about z-wave, but they do produce Switches on a large scale, the product is much more solid and does not provide the typical DYI feeling by installing or using it, screws for cables are very strong and can easy hold 6qmm cables.
 +
|-
 +
| Schlage
 +
| Lamp Module
 +
| RP200
 +
| 1.0
 +
| Aug 2009
 +
| Indoor
 +
| [http://consumer.schlage.com/products/Productdetail3.asp?StyleID=139&FinishID=12&FunctionID=77 Link]
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=2870 LibraSun]
 +
| Works well<br>Sold with Schlage LiNK lock system
 +
|-
 +
| TKB Home
 +
| 1 Way Switch
 +
| TZ66-S
 +
| &nbsp;
 +
| Jun 2013
 +
| Indoor
 +
| [http://www.tkbhome.com/?cn-p-d-110.html Link]
 +
| &nbsp;
 +
| [[User:Nullx8|nullx8]]
 +
| Switches 1x 1360VA (6A), has additional Input for extra switch, easy to include,<br />no immediate Update to Controller of status change, LED's very discrete, EU Form only
 +
|-
 +
| TKB Home
 +
| 1 Way Switch<br />Plus extra z-wave switch
 +
| TZ66-D
 +
| &nbsp;
 +
| Jun 2013
 +
| Indoor
 +
| [http://www.tkbhome.com/?cn-p-d-111.html Link]
 +
| &nbsp;
 +
| [[User:Nullx8|nullx8]]
 +
| Switches 1x 1360VA (6A), can control other z-wave switch/dimmer via assignment, has additional Input for extra switch, easy to include,<br />no immediate Update to Controller of status change, LED's very discrete, EU Form only
 +
|}
  
 +
<br>
 +
 +
=== '''Plug &amp; Receptacle Devices'''  ===
 +
 +
{| class="wikitable"
 
|-
 
|-
|| Intermatic || 3-way Switch || HA18 || || Dec 2008 || Indoor || [http://www.homesettings.com/products/new%20products/ha18.aspx Link] || || [http://forum.micasaverde.com/index.php?action=profile;u=66 Kozanator] || Affordable 3-way Switch
+
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Frequency
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added by User
 +
! Notes
 +
|-
 +
| ACT
 +
| In-Wall Receptacle
 +
| ZRR150W
 +
| 2.2
 +
| &nbsp;
 +
| Nov 2008
 +
| Indoor
 +
| [http://www.smarthome-products.com/p-527-homepro-zrr150-wall-receptacle.aspx Link]
 +
| [http://www.smarthome-products.com/p-527-homepro-zrr150-wall-receptacle.aspx Link]
 +
| <br>
 +
| Works like a champ! Easy to Install. One receptacle RF controlled, the other is hot
 +
|-
 +
| ACT
 +
| In-Wall Receptacle
 +
| ZRP200
 +
| &nbsp;
 +
| EU
 +
| July 2011
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| intveltr
 +
| Basic plug-in switch.
 +
|-
 +
| ACT
 +
| In-Wall Receptacle
 +
| ZDP200
 +
| &nbsp;
 +
| EU
 +
| July 2011
 +
| Indoor
 +
| &nbsp;
 +
| &nbsp;
 +
| intveltr
 +
| Basic plug-in dimmer.
 +
|-
 +
| Cooper Wiring Devices
 +
| In-Wall Receptacle
 +
| RFTR9505-T
 +
| &nbsp;
 +
| &nbsp;
 +
| &nbsp;
 +
| Indoor
 +
| [http://solutions.cooperwiringdevices.com/common/brands.cfm?pg=Detail&brandName=CWD%20Technology&category=Aspire%20RF%20Lighting%20Control%20System%3A%20Receptacles&id=16772 Link]
 +
| <br>
 +
| <br>
 +
| One receptacle is RF controlled, the other is hot. Not load sensing.
 +
|-
 +
| Duwi
 +
| <span class="S33">Z-Wave switch 3500 W</span>
 +
| <span class="S31">05437</span>
 +
| &nbsp;
 +
| EU
 +
| Feb 2009
 +
| Indoor
 +
| [http://www.duewi.com/ Link]
 +
| <br>
 +
| ezhome
 +
| High quality Plug-in switch, Easy install and works well
 +
|-
 +
| Easy-Light
 +
| <span class="S33">Z-Wave Switch 10A</span>
 +
| <span class="S31">ZSL301</span>
 +
| &nbsp;
 +
| EU
 +
| Feb 2013
 +
| Indoor
 +
| [http://www.easy-light.com/ Link]
 +
| <br>
 +
| [[User:Nullx8|nullx8]]
 +
| Large Casing, extremly Solid, Switches incoming current trough
 +
|-
 +
| Easy-Light
 +
| <span class="S33">Z-Wave Dimmer 0.7A</span>
 +
| <span class="S31"> ZDL301 </span>
 +
| &nbsp;
 +
| EU
 +
| Feb 2013
 +
| Indoor  
 +
| [http://www.easy-light.com/ Link]
 +
| <br>
 +
| [[User:Nullx8|nullx8]]
 +
| Large Casing, extremly Solid, Switches incoming current, Dimms in 10% steps
 +
|-
 +
| Everspring
 +
| <span class="S33">Z-Wave switch 3500 W</span>
 +
| <span class="S31">AN157-2</span>
 +
| 4,2,64,1,2
 +
| EU
 +
| &nbsp;
 +
| Indoor
 +
| [http://www.everspring.com/Products/Home_Automation_Detail.asp?parentUID=83&UID=501&CateUIDList=0,83 Link]
 +
| <br>
 +
| Ap15e
 +
| Works well.
 +
|-
 +
| Everspring
 +
| <span class="S33">Z-Wave switch 3500 W</span>
 +
| <span class="S31">AN158</span>
 +
| &nbsp;
 +
| EU
 +
| &nbsp;
 +
| Indoor
 +
| &nbsp;
 +
| <br>
 +
| intveltr
 +
| Works well. Supports status push and power metering
 +
|-
 +
| GE/Jasco
 +
| In-wall Duplex Receptacle
 +
| 45605
 +
| &nbsp;
 +
| US
 +
| 2/2011
 +
| Indoor
 +
| [http://www.jascoproducts.com/products/pc/GE-Z-Wave-Wireless-Lighting-Control-Duplex-Receptacle-63p554.htm Link] [http://www.jascoproducts.com/support/manual-downloads/applications/DocumentLibraryManager/upload/45605-Manual-Eng.pdf Link]
 +
| &nbsp;
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=64 Anthonyris]
 +
| Easy. Works.
 +
|-
 +
| Home Manageables
 +
| Lamp Module (Dimming)
 +
| HM-LM001
 +
| &nbsp;
 +
| &nbsp;
 +
| Nov 2011
 +
| Indoor
 +
| 200W maximum load, 25W minimum load
 +
| [http://www.homemanageables.com/manuals/HM-LM001%20Manual%20Final.pdf Link]
 +
| DaveL17
 +
| Works well. Support for incandescent loads only. Not load sensing.
 +
|-
 +
| Intermatic
 +
| In-Wall Receptacle
 +
| CA3500
 +
| 1
 +
| &nbsp;
 +
| Nov 2008
 +
| Indoor
 +
| [http://shop.micasaverde.com/index.php?main_page=product_info&cPath=105&products_id=97 Link]  
 +
| [http://www.amazon.com/review/product/B000U3XYPA/ref=dp_top_cm_cr_acr_txt?_encoding=UTF8&showViewpoints=1 Link]
 +
| <br>
 +
| This is a decent, but expensive solution for in-wall receptacles. One receptacle RF controlled, the other is hot.
 +
|-
 +
| Intermatic
 +
| Appliance Module
 +
| HA02C
 +
| 1
 +
| &nbsp;
 +
| Nov 2008
 +
| Indoor
 +
| [http://shop.micasaverde.com/index.php?main_page=product_info&cPath=108&products_id=98 Link]
 +
| [http://www.amazon.com/Intermatic-HA02C-Settings-Heavy-Duty-Appliance/dp/B000BJSDZO/ref=sr_1_3?ie=UTF8&qid=1227467418&sr=8-3 Link]
 +
| <br>
 +
| Seems to work well
 +
|-
 +
| Intermatic
 +
| Outdoor Module
 +
| HA04C
 +
| 1
 +
| &nbsp;
 +
| Dec 2008
 +
| Outdoor
 +
| [http://store.homeseer.com/store/HA04C---Z-Wave-Outdoor-Module-Intermatic-HomeSettings-P6C62.aspx Link]
 +
| [http://store.homeseer.com/store/HA04C---Z-Wave-Outdoor-Module-Intermatic-HomeSettings-P6C62.aspx Link]
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=66 Kozanator]  
 +
| Easy to Install.
 +
|-
 +
| Merten
 +
| switch, plug adapter, 2000 W
 +
| 508519
 +
| 6,2,7,1,5
 +
| EU
 +
| &nbsp;
 +
| Indoor
 +
| [http://www.merten.de/download/DL_doku/V5085_581_01_web.pdf Link]
 +
| &nbsp;
 +
| Ap15e
 +
| Works well.
 +
|-
 +
| Monster Central
 +
| 1800W Appliance Module
 +
| ML-LAS1000
 +
| 1
 +
| &nbsp;
 +
| Jan 2009
 +
| Indoor
 +
| [http://www.monstercable.com/productdisplay.asp?pin=3164 Link]
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=2618 guessed]
 +
| Easy to Install. I use this as a ZWave signal repeater. Appears to be a badge-engineering of [http://www.leviton.com/OA_HTML/ibeCCtpItmDspRte.jsp?item=309748&section=25542 Leviton VRP15-1LW]
 +
|-
 +
| Wayne Dalton
 +
| Appliance Module
 +
| HA-02L<br>(HA-02WD)
 +
| <br>
 +
| <br>
 +
| Dec 2011
 +
| Indooor
 +
| [http://www.waynedaltonstore.com/ssi/pdf/wayne/HA-02WD.pdf Link]
 +
| <br>
 +
| DaveL17
 +
| Note: link is to HA-02WD manual.
 +
|-
 +
| Wayne Dalton
 +
| Lamp Module
 +
| HA-03WD
 +
| <br>
 +
| <br>
 +
| Dec 2011
 +
| Indoor
 +
| [http://www.waynedaltonstore.com/ssi/pdf/wayne/HA-03WD.pdf Link]
 +
| <br>
 +
| DaveL17
 +
| Not load sensing.
 +
|-
 +
| Wayne Dalton
 +
| Outdoor Lighting Module
 +
| HA-04WD
 +
| <br>
 +
| <br>
 +
| Oct 2012
 +
| Outdoor
 +
| [http://www.waynedaltonstore.com/ssi/pdf/wayne/HA-04WD.pdf Link]
 +
| <br>
 +
| DaveL17
 +
| Not load sensing.
 +
|}
  
 +
<br>
 +
 +
=== '''Thermostat Devices'''  ===
 +
 +
{| class="wikitable"
 +
|-
 +
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Frequency
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added<br>By User
 +
! Notes
 +
|-
 +
| Wayne Dalton
 +
| Wall Stat
 +
| WDTC-20
 +
| &nbsp;??
 +
| &nbsp;
 +
| Nov 2008
 +
| Indoor
 +
| [http://store.homeseer.com/store/WDTC-20---Z-Wave-Thermostat-Wayne-Dalton-P599C38.aspx Link]
 +
| [http://www.amazon.com/Wayne-Dalton-Corporation-Z-Wave-Thermostat/dp/B001F8QKYQ Link]
 +
| <br>
 +
| Has 2 inclusion modes: 1) press and release the bind button and the STAT will be included as a thermostat and works with Vera, 2) press and hold the bind button and it will be added as a binary switch for compatibility with old, non-compliant remotes. If it's added in the wrong mode, remove it and re-add it. Works great simple to use!
 +
|-
 +
| HAI
 +
| Wall Stat
 +
| RC-80BZ
 +
| &nbsp;??
 +
| &nbsp;
 +
| Nov 2007
 +
| Indoor
 +
| [http://www.homeauto.com Link]
 +
| [http://www.homeauto.com/Downloads/Products/Omnistat/rcr80.pdf Link]
 +
| <br>
 +
| Shows up as Standard Thermostat in Vera, Hold button feature not able to control by Vera at this time. Priced above 200.00. Has internal setback programs. Works great.
 +
|-
 +
| RCS
 +
| Wall Stat
 +
| TZ43
 +
| &nbsp;??
 +
| &nbsp;
 +
| Nov 2008
 +
| Indoor
 +
| [http://store.homeseer.com/store/TZ43---Z-Wave-Thermostat-RCS-P627C67.aspx Link]
 +
| [http://store.homeseer.com/store/TZ43---Z-Wave-Thermostat-RCS-P627C67.aspx Link]
 +
| <br>
 +
| Shows up as Standard Thermostat in Vera, much more feature rich the the WDTC-20 but comes with a hefty price tag ($214.95). Wish Vera could use all the features in this Thermostat! '''Note:'''''You need to set the thermostat to show the temperature, on its display, in Celsius degree in order to be able to receive "Set Temp" commands from Vera. This is no longer required in firmwares above '''''<i>1.0.862 (luup)</i>'''
 +
|-
 +
| Schlage/Trane
 +
| Wall Stat
 +
| Trane
 +
| &nbsp;??
 +
| &nbsp;
 +
| &nbsp;??
 +
| Indoor
 +
| [http://www.link.schlage.com/Products/Pages/Thermostat.aspx Link]
 +
| [http://www.trane.com/Residential/Products/Thermostats Link]
 +
| <br>
 +
| It's the same thermostat as the RCS TZ43 and it has the same issue: it's accepting "Set Temp Point" commands only in the measurement unit that is displayed on its screen. '''Note:'''''You need to set the thermostat to show the temperature, on its screen, in Celsius degree in order to be able to receive "Set Temp" commands from Vera. This is no longer required in firmwares above '''''<i>1.0.862 (luup)</i>'''
 +
|-
 +
| Intermatic
 +
| InTouch
 +
| CA8900
 +
| <br>
 +
| &nbsp;
 +
| Nov 2008
 +
| Indoor
 +
| [http://www.smarthome-products.com/p-663-intermatic-intouch-ca8900-z-wave-digital-thermostat.aspx Link]
 +
| <br>
 +
| <br>
 +
| Looks very similar to the Wayne Dalton WDTC-20 listed here. works great, simple to use
 +
|-
 +
| Danfoss
 +
| Radiator thermostat
 +
| RA PLUS-w
 +
| <br>
 +
| EU
 +
| <br>
 +
| Indoor
 +
| [http://raplusw.com/Content/E962FC0B-6461-4319-82FE-3E1E765142CF.html Link] [http://raplusw.com/PCMPDF/Data%20sheet%20RA-PLUS-w_02.pdf Link]
 +
| [http://www.eurox10.com/Product/ZWave/Actuators/ZWDNF_RA_PLUS-W.htm Link] [http://www.eurox10.com]
 +
| <br>
 +
| See: [[Danfoss Thermostat]] for installation instructions<br>If the device cannot be configured at the final location, move the device closer to Vera and try again (this device might require a direct connection to Vera for configuration).
 
|-
 
|-
|| Intermatic || 3-way Dimmer Switch || HA20 || || Nov 2008 || Indoor || [http://www.homesettings.com/products/new%20products/ha20.aspx Link] || [http://www.amazon.com/Intermatic-Settings-Three-Way-Dimmer-HA20C/dp/B000WS4SJ41 Link] || || Affordable 3-way 600W dimmer
+
| Radio Thermostat
 +
| Wall Stat
 +
| CT22
 +
| <br>
 +
| US
 +
| <br>
 +
| Indoor  
 +
| [http://www.radiothermostat.com/documents/CT-22-Operation-27aug10.pdf Link] [http://www.radiothermostat.com/documents/CT-22-Installation-27aug10.pdf Link]  
 +
| <br>
 +
| Daniel
 +
|  
 +
To include the thermostat into your network, you just have to install the USNAP module in the thermostat while Vera is in Include mode. To exclude the thermostat from your network, you just have to install the USNAP module in the thermostat while Vera is in Exclude mode.You can watch a video about how to install it [http://www.youtube.com/watch?v=M9VNuHGENP0 here]<br>
  
 
|-
 
|-
|| ACT || 2-way Dimmer Switch || ZDW120 || || Nov 2008 || Indoor || [http://store.homeseer.com/store/ZDW120---Z-Wave-600-Watt-2-Wire-Dimmer-ACT-HomePro-P17C64.aspx Link] ||[http://store.homeseer.com/store/ZDW120---Z-Wave-600-Watt-2-Wire-Dimmer-ACT-HomePro-P17C64.aspx Link] || [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]||Works well, easy to install, LED is a very bright blue....can be programmed to be off when the light is off or on.
+
| Radio Thermostat
 +
| Wall Stat
 +
| CT30
 +
| <br>
 +
| US<br>
 +
| <br>
 +
| Indoor<br>
 +
| <br>
 +
| <br>
 +
| mcvflorin<br>
 +
| If you experience a problem with other Z-Wave devices, see this [http://wiki.micasaverde.com/images/3/39/RTCOA_Z-Wave_v7.4_workaround.zip note].<br>
 +
|-
 +
| Remotec
 +
| Wall Stat
 +
| ZTS-100
 +
| <br>
 +
| <br>
 +
| <br>
 +
| Indoor
 +
| <br>
 +
| <br>
 +
| <br>
 +
| To include the thermostat into your network, hold the home button for 2 seconds until the display says 'noc', which means 'no connection', then press the Prog button and the readout will say 'Srh'. If it doesn't say 'noc' or if the radio icon is visible in the upper right corner, the thermostat is already included and must be removed/reset. To remove/reset the thermostat hold the home button for 2 seconds until the display says 'done', then press the Prog button.
 +
|-
 +
| Horstmann
 +
| Wall Stat
 +
| HRT4-ZW
 +
| <br>
 +
| EU
 +
| <br>
 +
| Indoor
 +
| [http://horstmann.co.uk/downloads/ElectronicDocuments/Central-Heating/HRT4-ZWweb.pdf Link] [http://horstmann.co.uk/downloads/ElectronicDocuments/Central-Heating/HRT4B-ZWManual.pdf Link]  
 +
| [http://horstmann.co.uk/downloads/ElectronicDocuments/Central-Heating/HRT4B-ZWManual.pdf <br>]  
 +
| Daniel
 +
| After you include the thermostat in Vera's network, you will have to make some configuration changes in order for it to report the temperature change. See: [[HRT4-ZW]] for more information.
 +
|}
  
 +
<br>
 +
 +
=== '''Sensors'''  ===
 +
 +
{| class="wikitable"
 
|-
 
|-
|| ACT || 3-way Dimmer Switch || ZDW103 ||  || Nov 2008 || Indoor || [http://store.homeseer.com/store/ZDW103---Z-Wave-500-Watt-3-way-Dimmer-ACT-HomePro-P19C64.aspx Link] ||[http://store.homeseer.com/store/ZDW103---Z-Wave-500-Watt-3-way-Dimmer-ACT-HomePro-P19C64.aspx Link] || [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]||Works well, can be tricky to install due to the different combination of 3 way circuits, LED is a very bright blue....can be programmed to be off when the light is off or on.
+
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Frequency
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added by User
 +
! Notes
 +
|-
 +
| ACT  
 +
| Motion Sensor
 +
| ZIR000 / ZIR010
 +
| <br>
 +
| EU (ZIR010) or US (ZIR000)
 +
| <br>
 +
| Indoor  
 +
| [http://www.act-solutions.com/HomePro/pdfs/HomePro/Specs/ZIR000_spec.pdf Link] [http://www.act-solutions.com/HomePro/pdfs/HomePro/Inst/ZIR000_instr.pdf Link] [http://www.act-solutions.com/HomePro/pdfs/HomePro/Specs/ZIR010_spec.pdf Link] [http://www.act-solutions.com/HomePro/pdfs/HomePro/Inst/ZIR010_instr.pdf Link]
 +
| <br>
 +
| <br>
 +
| Remove the cover, pair to Vera's dongle by using the push-button on the left of the circuit board. Vera must configure it to work, and it can only be configured within less of a minute (30 sec best) of inserting the batteries. With Vera's dongle removed, remove/reinsert the batteries, and within 30 seconds insert Vera's dongle. Within a few minutes confirm the "configure" icon for the device is green on Vera's setup page
 +
|-
 +
| Aeon Labs
 +
| 3-in-1 sensor (light/humidity/temperature)
 +
| MultiSensor
 +
| <br>
 +
| EU or US
 +
| <br>
 +
| Indoor/Outdoor
 +
| [http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=29 Specs]
 +
| <br>
 +
| <br>
 +
| Pair to Vera by using the push-button. Vera must configure it to work, and it can only be configured within 10 minutes of inserting the batteries.
 +
|-
 +
| Express Controls aka HomeSeer
 +
| 3-in-1 sensor (light/temperature/motion)
 +
| HSM100 / EZMotion
 +
| <br>
 +
| EU or US
 +
| <br>
 +
| <br>
 +
| [http://www.expresscontrols.com/pdf/EZMotionOwnerManual.pdf Link]  
 +
| <br>
 +
| <br>
 +
| See [[ExpressControls3in1]]<br>If the motion sensor does not work right after inclusion and configuration, remove the batteries for a few seconds.
 +
|-
 +
| EverSpring/Hawking/Home Manageables
 +
| Door/window sensor
 +
| SM103
 +
| 6,2,9,1,0
 +
| EU or US
 +
| Apr 2009
 +
| Indoor
 +
| [http://www.everspring.com/Products/Home_Automation_Detail.asp?parentUID=83&UID=355&CateUIDList=0,83 Link] [http://www.everspring.com/Archive/Image/File/A501110873R01_SM103_-ECR.pdf Link]  
 +
| &nbsp;
 +
| Ap15e
 +
| Pair using the intrusion button. The sensor will accept configuration within a few minutes of the initial pairing, or of pressing the intrusion button on the back even after it's paired. Pair the device, or if it's already paired, press the intrusion button, and within 30 seconds insert Vera's dongle. Within a few minutes confirm the "configure" icon for the device is green on Vera's setup page. NOTE: There is some confusion about the orientation of the sensor. The main sensor body has a back (where the intrusion is), a front (where the logo and LED is), and the 2 other surfaces, one of which has a curved edge, and the other is flat. The magnet needs to go against the flat surface. And the flat surface on the magnet should be as close as possible to the flat surface on the sensor, lined up in the middle so the line which passes through the LED lines up with the sensor.
 +
Note: In case the inclusion/exclusion fails you should remove/reinsert the batteries from the sensor and within a few seconds the sensor should be automatically detected.  
  
 
|-
 
|-
|| ACT || Companion Switch || AS101 || || Nov 2008 || Indoor || [http://store.homeseer.com/store/AS101---Z-Wave-3-Way-Companion-Switch-ACT-HomePro-P10C63.aspx Link] ||[http://store.homeseer.com/store/AS101---Z-Wave-3-Way-Companion-Switch-ACT-HomePro-P10C63.aspx Link] || [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]||Works well, can be tricky to install due to the different combination of 3 way circuits, The trick here is to install this device where the power comes in.
+
| EverSpring/Home Manageables
 +
| Humidity + Temperature sensor
 +
| HM-TS001
 +
| <br>
 +
| <br>
 +
| Jan 2010 (requires version 1.1.0 or greater)
 +
| Indoor
 +
| [http://www.asihome.com/ASIshop/product_info.php?products_id=3946 Link] [http://www.homeseer.com/pdfs/guides/HM_TD001.pdf Link]
 +
| &nbsp;
 +
| micasaverde
 +
| Pair or unpair the device by tapping the CF button 3 times very quickly. Once it's paired and shows up in the UI as a generic device, press the CF button 3 times again quickly to make it wakeup and get configured. Then it will correctly be identified as 3 devices (combo device + temperature + humidity).
 +
|-
 +
| Everspring
 +
| Motion Detector
 +
| SP103
 +
| 6,2,9,1,0
 +
| EU or US
 +
| Apr 2009
 +
| Indoor
 +
| [http://www.everspring.com/Products/Home_Automation_Detail.asp?parentUID=83&UID=354&CateUIDList=0,83 Link] [http://www.everspring.com/Archive/Image/File/A501110874R01_SP103_%20-%20ECR.pdf Link]  
 +
| &nbsp;
 +
| Ap15e
 +
| Works well
 +
|-
 +
| Fortrezz
 +
| Water /Freeze
 +
| WWA-001
 +
| &nbsp;??????
 +
| US
 +
| Apr 2009
 +
| Indoor
 +
| [http://www.Fortrezz.com Link] [http://www.fortrezz.com/resources/WWA_manual_01May2009.pdf Link]  
 +
| <br>
 +
| Zmistro
 +
| Works great I would place a few in your house. Bathrooms, laundry , kitchen , basement. Great product!
 +
|-
 +
| Intermatic
 +
| Motion Sensor
 +
| CA-9000
 +
| <br>
 +
| US
 +
| <br>
 +
| Indoor
 +
| [http://www.smarthomeusa.com/Products/CA9000/manuals/CA9000.pdf Link]<br>
 +
| <br>
 +
| Aaron
 +
| This device has limited functionality as a sensor. It can only be used to turn on and off a light directly by setting an association, which Vera supports. It does not fire events, so you cannot use it as an event on a scene.
 +
|-
 +
| Merten
 +
| 4-gang radio transmitter, flush-mounted
 +
| 506004
 +
| 2,2,27,1,4
 +
| EU
 +
| &nbsp;
 +
| Indoor
 +
| [http://www.merten.de/download/DL_doku/V5060_581_02_web.pdf Link]
 +
| &nbsp;
 +
| Ap15e
 +
| Note: There is proprietary functionality here. Support will be added soon.
 +
Quite complex device; partially supported by Vera; can be used as a window/door sensor (as of firmware 1.0.900) ...  
  
 
|-
 
|-
|| Intermatic ||Screw-in Module  || HA05C ||  || Nov 2008 || Outdoor || [http://store.homeseer.com/store/HA05C---Z-Wave-IndoorOutdoor-Screw-in-Module-Intermatic-HomeSettings-P1C62.aspx Link] ||[http://store.homeseer.com/store/HA05C---Z-Wave-IndoorOutdoor-Screw-in-Module-Intermatic-HomeSettings-P1C62.aspx Link] || [http://forum.micasaverde.com/index.php?action=profile;u=49 WSeverino]||Easy install, easy to pair with Vera!
+
| Aeon Labs (Aeotec)<br>
 +
| 4 in 1 Sensor (Multisensor)<br>
 +
| DSB05106-ZWUS
 +
| <br>
 +
| US<br>
 +
| <br>
 +
| Indoor/Outdoor<br>
 +
| [http://aeotec.com/z-wave-sensor/47-multisensor-manual.html Link]<br>
 +
| <br>
 +
| mcvadi<br>
 +
| [http://wiki.micasaverde.com/index.php/Aeon_4in1 Link]<br>
 
|}
 
|}
  
=== '''Plug & Receptacle Devices''' ===
+
<br>
  
{| border="1" cellpadding="2"
+
=== '''Door Locks''' ===
! Manufacturer !! Device Type !! Model no. !! Version !! Date Purchased !! Location (indoor/outdoor) !! Specs !! Product Review !! Added by User !! Notes
+
  
 +
{| class="wikitable"
 
|-
 
|-
|| Intermatic || In-Wall Receptacle || CA3500 || 1 || Nov 2008 || Indoor || [http://shop.micasaverde.com/index.php?main_page=product_info&cPath=105&products_id=97 Link] || [http://www.amazon.com/review/product/B000U3XYPA/ref=dp_top_cm_cr_acr_txt?_encoding=UTF8&showViewpoints=1 Link] || || This is a decent, but expensive solution for in-wall receptacles
+
! Manufacturer
 
+
! Device Type
 +
! Model no.  
 +
! Version
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added<br>By User
 +
! Notes
 
|-
 
|-
|| Intermatic || Appliance Module || HA02C || 1 || Nov 2008 || Indoor || [http://shop.micasaverde.com/index.php?main_page=product_info&cPath=108&products_id=98 Link] || [http://www.amazon.com/Intermatic-HA02C-Settings-Heavy-Duty-Appliance/dp/B000BJSDZO/ref=sr_1_3?ie=UTF8&qid=1227467418&sr=8-3 Link] || || Seems to work well
+
| Schlage
 +
| Door lock and deadbolt
 +
| BE369 (deadbolt)
 +
| <br>
 +
| Mid 2009
 +
| Indoor  
 +
| [http://consumer.schlage.com/link/product_tour/ Link]
 +
| <br>
 +
| [http://forum.micasaverde.com/index.php?action=profile;u=2870 LibraSun]  
 +
| Read the instructions here: [[Schlage Lock]]
 +
|-
 +
| Kwikset
 +
| Door lock and deadbolt
 +
| <br>
 +
| <br>
 +
| <br>
 +
| Indoor
 +
| <br>
 +
| <br>
 +
| <br>
 +
| Read instructions here:[[Kwikset Lock]]
 +
|-
 +
| Yale
 +
| Deadbolt
 +
| Real Living
 +
| <br>
 +
| <br>
 +
| Indoor
 +
|
 +
[http://www.yaleresidential.com/Yale/Yale%20US/Real%20Living/Documents%20Library/Yale%20DB%20PUSH%20Quickstart%2018JUL11_Rev%20B.pdf Link]  
  
 +
[http://www.yaleresidential.com/Yale/Yale%20US/Real%20Living/Documents%20Library/Yale%20DB%20PUSH%20Instructions%2023AUG11_Rev%20B.pdf Link]
 +
 +
| <br>
 +
| <br>
 +
| Read instructions here: [[Yale Lock]]
 +
|}
 +
 +
<br>
 +
 +
=== '''Drapes/Blinds'''  ===
 +
 +
{| class="wikitable"
 
|-
 
|-
|| ACT || In-Wall Receptacle || ZRR150W || 2.2 || Nov 2008 || Indoor || [http://store.homeseer.com/store/ZRR150W---Z-Wave-Split-Duplex-Receptacle-ACT-HomePro-P528C123.aspx Link] || [http://store.homeseer.com/store/ZRR150W---Z-Wave-Split-Duplex-Receptacle-ACT-HomePro-P528C123.aspx Link] || || Works like a champ! Easy to Install
+
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added<br>By User
 +
! Notes
 +
|-
 +
| Electronic Solutions
 +
| Drape/Blind Motor Controller
 +
| DBMZ
 +
| V2+1
 +
| <br>
 +
| Indoor
 +
| For 12-24VDC Motors
 +
| [http://www.elec-solutions.com/products/dc_mot_ctrls/z-wave/dbmz/dbmz.html Link]
 +
| Shady
 +
| 2-Wire Motors
 +
|-
 +
| Electronic Solutions
 +
| Drape/Blind Motor Controller
 +
| ABMHZ
 +
| V2+1
 +
| <br>
 +
| Indoor  
 +
| For 110-230VAC Motors
 +
| [http://www.elec-solutions.com/products/int_ac_mot_ctrls/z-wave/abmhz/abmhz.html Link]
 +
| Shady
 +
| 4-Wire Motors
 +
|-
 +
| Lagotek / RSSceneAutomation
 +
| Drape/Blind Motor Controller
 +
| DC1-ZW
 +
| <br>
 +
| <br>
 +
| Indoor
 +
| For 12-24VDC Motors
 +
| [http://www.lagotek.com/blindspdf/AC1-ZW%20Cut%20Sheet.pdf Link]  
 +
| Shady
 +
| 2-Wire Motors
 +
|-
 +
| Lagotek / RSSceneAutomation
 +
| Drape/Blind Motor Controller
 +
| AC1-ZW
 +
| <br>
 +
| <br>
 +
| Indoor
 +
| For 110-230VAC Motors
 +
| [http://www.lagotek.com/blindspdf/DC1-ZW%20Cut%20Sheet.pdf Link]  
 +
| Shady
 +
| 4-Wire Motors
 +
|}
  
 +
<br>
 +
 +
=== '''Relay controls'''  ===
 +
 +
{| class="wikitable"
 +
|-
 +
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added<br>By User
 +
! Notes
 +
|-
 +
| Intermatic
 +
| Contactor control box
 +
| CA3750
 +
| <br>
 +
| Nov 2007
 +
| Indoor/Outdoor
 +
| [http://www.intouchcontrols.com/~/media/Files/InTouchControls/Products/Spec%20Sheets/CA3750.ashx Link]
 +
| <br>
 +
| <br>
 +
| Multi-instance class supported for this device. Vera is able to control each of the 2 relays independently if desired. please note unit shows as three switches this is a bug with Intermatic not a real issue.You can check the box in devices to not show the second listing of the first relay in "Dasboard" You can control heavy loads like a water heater ,pool pump motor/s. great device
 +
|-
 +
| Fibaro<br>
 +
| Relay Switch<br>
 +
| FGS211
 +
| <br>
 +
| EU
 +
| <br>
 +
| [https://www.uk-automation.co.uk/pdf/FGS211.pdf Link]
 +
| <br>
 +
| Daniel
 +
| This device is identified as a master device with 1 child device. The master controls the S1 output, the child controls the S2 output.
 
|-
 
|-
|| Intermatic || Outdoor Module || HA04C || 1 || Dec 2008 || Outdoor || [http://store.homeseer.com/store/HA04C---Z-Wave-Outdoor-Module-Intermatic-HomeSettings-P6C62.aspx Link] || [http://store.homeseer.com/store/HA04C---Z-Wave-Outdoor-Module-Intermatic-HomeSettings-P6C62.aspx Link] || [http://forum.micasaverde.com/index.php?action=profile;u=66 Kozanator] || Easy to Install.  
+
| Fibaro
 +
| Double Relay Switch
 +
| FGS221
 +
| <br>
 +
| EU
 +
| <br>
 +
| [http://materialy.fibaro.com/instrukcje/relay%20switch%20FGS221%20v1_4%20eng.pdf Link]  
 +
| <br>
 +
| Daniel
 +
| This device is identified as a master device with 1 child device. The master controls the S1 output, the child controls the S2 output.
 
|}
 
|}
  
=== '''Thermostat Devices''' ===
+
<br>
  
{| border="1" cellpadding="2"
+
=== '''Window Coverings''' ===
! Manufacturer !! Device Type || Model no. !! Version !! Date Purchased !! Location (indoor/outdoor) !! Specs !! Product Review !! Notes
+
 
 +
{| class="wikitable"
 
|-
 
|-
|| Wayne Dalton || Wall Stat || WDTC-20 || ?? || Nov 2008 || Indoor || [http://store.homeseer.com/store/WDTC-20---Z-Wave-Thermostat-Wayne-Dalton-P599C38.aspx Link] || [http://www.amazon.com/Wayne-Dalton-Corporation-Z-Wave-Thermostat/dp/B001F8QKYQ Link] || Has 2 inclusion modes: 1) press and release the bind button and the STAT will be included as a thermostat and works with Vera, 2) press and hold the bind button and it will be added as a binary switch for compatibility with old, non-compliant remotes.
+
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Frequency
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added by User
 +
! Notes
 +
|-
 +
| Merten
 +
| Radio roller shutter push-button
 +
| 5025xx, 5035xx, 5045xx
 +
| 6,2,27,2,3 and 6,2,27,2,4
 +
| EU
 +
| Apr 2009
 +
| Indoor  
 +
| [http://www.merten.de/download/DL_doku/V5025_581_01_web.pdf Link]  
 +
| &nbsp;
 +
| Ap15e
 +
| Open/Close buttons work well, but slide bar does not work. GUI buttons do not work with Luup release 1.0.843 and 1.0.862 (fixed with Luup release 1.0.879).<br>Workaround: Use a Luup Scene with the following code:<tt></tt>
 +
<tt>local lul_arguments = {}</tt>
 +
 
 +
<tt>lul_arguments["newTargetValue"]="0"</tt>
 +
 
 +
<tt>lul_resultcode,lul_resultstring,lul_job,lul_returnarguments = luup.call_action("urn:upnp-org:serviceId:SwitchPower1","SetTarget",lul_arguments,6) </tt> Replace "6" with your device number, replace "0" with "1" for inverse action.  
  
 
|-
 
|-
|| RCS || Wall Stat || TZ43 || ?? || Nov 2008 || Indoor || [http://store.homeseer.com/store/TZ43---Z-Wave-Thermostat-RCS-P627C67.aspx Link] || [http://store.homeseer.com/store/TZ43---Z-Wave-Thermostat-RCS-P627C67.aspx Link] ||Shows up as Standard Thermostat in Vera, much more feature rich the the WDTC-20 but comes with a hefty price tag ($214.95). Wish Vera could use all the features in this Thermostat!
+
| Duewi
 +
| Radio roller shutter push-button
 +
| 054368
 +
| 6,2,51,1,0
 +
| EU
 +
| Jun 2009
 +
| Indoor  
 +
| [http://www.duewi.de/index.php?productid=37344 Link]  
 +
| &nbsp;
 +
| Lutz
 +
| Open/Close buttons work well, but slide bar does not work.<br><br>Some additional observations by Ap15e (Vera V1, firmware 1.0.979):
 +
*GUI button 'Stop' and corresponding UPnP service does not work.
 +
*GUI button 'Up' moves the shutter down, GUI button 'Down' moves the shutter up ...
 +
*After adjusting the running times even the slide bar seems to work!
 +
*I got a report from a user that the düwi device may fail due to interference from the shutter motor. In this case an additional filter is required (costs about 25 €/direction).
 +
*More information is available at [http://forum.micasaverde.com/index.php?topic=3359.msg16142#msg16142 Link]
  
 +
|}
  
 +
<br>
 +
 +
=== '''Cameras that work'''  ===
 +
 +
See [http://wiki.micasaverde.com/index.php/IP_Cameras IP Cameras] for a more comprehensive and up to date list
 +
 +
{| class="wikitable"
 +
|-
 +
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Path for JPEG image
 +
! Product Review
 +
! Notes
 +
|-
 +
| Linksys
 +
| IP Camera
 +
| WVC54GCA
 +
| all
 +
| 2009
 +
| Indoor
 +
| img/snapshot.cgi
 +
| <br>
 +
| An inexpensive camera with moderate image quality. Use the Linksys setup wizard for initial setup, then copy IP address and path into Vera setup fields. Use a static IP address.
 +
|-
 +
| Linksys
 +
| IP Camera
 +
| WVC210
 +
| all
 +
| 2009
 +
| Indoor
 +
| img/snapshot.cgi
 +
| <br>
 +
| A more expensive camera with good image quality and pan/tilt ability. Use the Linksys setup wizard for initial setup, then copy IP address and path into Vera setup fields. Use a static IP address. Pan/tilt controls will not work with Vera.
 +
|-
 +
| Linksys
 +
| IP Camera
 +
| WVC80N
 +
| all
 +
| 2009
 +
| Indoor
 +
| img/snapshot.cgi?size=2&amp;quality=1
 +
| <br>
 +
| A more expensive camera with good image quality and wireless N. Use the Linksys setup wizard for initial setup, then copy IP address and path into Vera setup fields. Use a static IP address. Pan/tilt controls will not work with Vera.
 +
Size can be (160 x 120 = 1,320 x 240 = 2,640 x 480 = 3) and Quality can be (Very High= 1,High= 2,Normal= 3,Low= 4,Very Low= 5)
 +
 +
|-
 +
| iCamView
 +
| IP Camera Server
 +
| iCV-22, iCV-32
 +
| all
 +
| 2009<br>
 +
| Indoor/Outdoor
 +
| pda.cgi?user=admin&amp;password=1234&amp;page=image&amp;cam=1<br><br>pda.cgi?user=admin&amp;password=1234&amp;page=image&amp;cam=2<br>
 +
| <br>
 +
| Feature-rich IP camera server, suports up to two compatible USB cameras, optional WiFi support, USB storage, USB hubs, motion; works with range of cameras, see icamview.co.uk. Excellent modular solution. They do ship to North America.
 +
|-
 +
| SmartHome.com.au
 +
| IP Camera
 +
| Z~Series Wireless Camera
 +
| all
 +
| 2009<br>
 +
| Indoor
 +
| tmpfs/auto.jpg
 +
| <br>
 +
| Inexpensive IP security camera designed for the Australian and New Zealand Z-Wave users, but shipping world wide.
 +
|-
 +
| [http://global.level1.com LevelOne]
 +
| IP Camera
 +
| WCS-2030
 +
| all
 +
| 2010
 +
| Indoor
 +
| cgi-bin/video.jpg
 +
| [http://reviews.cnet.com/search-results/levelone-camcon-wcs-2030/1707-5_7-31972011.html CNET review]
 +
| An inexpensive IP camera with good image quality. Can be connected wired or wirelessly. Most LevelOne cameras use the same path for the JPEG image, so most of their line (both low and high end) should be compatible. Video and audio also stream over RTSP, which can be customized through the camera's web interface.
 +
|-
 +
| Asante
 +
| IP Camera
 +
| Voyager I
 +
| firmware 2.02 and above
 +
| 2010
 +
| Indoor
 +
| image.cgi
 +
| <br>
 +
| An inexpensive&nbsp;IP&nbsp;camera that is very feature rich, has good image quality, night vision capabilities, motion detection, two-way audio, video streaming over TCP, UDP, or HTTP, and other configurable features. In firmware version 2.02, Asante added the capability to retrieve an image via a URL (however, it is delayed by 3 seconds). Offers a full-featured web interface in IE using an ActiveX plug-in (limited capabilites in other browsers).
 
|}
 
|}
  
=== '''Sensors''' ===
+
<br>
 +
 
 +
=== Alarm Panels  ===
  
{| border="1" cellpadding="2"
+
{| class="wikitable"
! Manufacturer !! Device Type !! Model no. !! Version !! Date Purchased !! Location (indoor/outdoor) !! Specs !! Product Review !! Notes
+
 
|-
 
|-
|| ACT || Motion Sensor || PIR000 / PIR010||  ||  || Indoor ||  ||  || Remove the cover, pair to Vera's dongle by using the push-button on the left of the circuit board.  Vera must configure it to work, and it can only be configured within a few minutes of inserting the batteries.  With Vera's dongle removed, remove/reinsert the batteries, and within 30 seconds insert Vera's dongle.  Within a few minutes confirm the "configure" icon for the device is green on Vera's setup page
+
! Manufacturer
 +
! Model(s)
 +
! Required module
 +
! Plugin
 +
! Notes
 
|-
 
|-
|| Express Controls || 3-in-1 sensor ||  ||  ||  || ||  ||  || Pair using the blue button. The sensor will accept configuration within a few minutes of pressing the blue button, whether or not you are actually pairing or just pushing the button. So, with Vera's dongle removed, pair it or press the blue button if it's already paired, and within 30 seconds insert Vera's dongle. Within a few minutes confirm the "configure" icon for the device is green on Vera's setup page. This will show up as a device with 3 embedded devices (motion sensor, light sensor, thermometer). Be sure the configure icon is green, indicating the sensor is configured. If not, press the blue button on the side of the sensor which causes the sensor to wake it up for a couple minutes and accept configuration settings.  Then, within a couple minute, in Vera's Web UI, click the '+' button next to the sensor and click 'configure right now'.
+
| DSC
 +
|  
 +
*[http://www.dsc.com/index.php?n=products&o=view&id=1 PowerSeries PC1616]
 +
*[http://www.dsc.com/index.php?n=products&o=view&id=2 PowerSeries PC1832]
 +
*[http://www.dsc.com/index.php?n=products&o=view&id=3 PowerSeries PC1864]
 +
 
 +
| [http://www.dsc.com/index.php?n=products&o=view&id=22 IT-100] or [https://www.eyez-on.com/EZMAIN/envisalink2ds.php Envisalink IP170/2DS]
 +
| [http://code.mios.com/trac/mios_dscalarmpanel/wiki/WikiStart Link]
 +
| <br>
 
|-
 
|-
|| EverSpring/Hawking/Home Managemeables || Door/window sensor || || || || || ||  || Pair using the intrusion button. The sensor will accept configuration within a few minutes of the initial pairing, or of pressing the intrusion button on the back even after it's paired. Pair the device, or if it's already paired, press the intrusion button, and within 30 seconds insert Vera's dongle. Within a few minutes confirm the "configure" icon for the device is green on Vera's setup page
+
| Elk
 +
|  
 +
*[http://www.elkproducts.com/_webapp_2981420/M1_Gold_Cross_Platform_Control%C2%AE M1 Gold]
 +
*[http://www.elkproducts.com/_webapp_3127911/M1EZ8_Cross_Platform_Control%C2%AE M1EZ8]
 +
 
 +
| The M1EZ8 panel requires the [http://www.elkproducts.com/_webapp_2981423/elk-m1ez8msi__m1ez8_main_serial_interface ELK-M1EZ8MSI] Main Serial Port Interface.
 +
| [http://code.mios.com/trac/mios_elk-alarm-panel/wiki/WikiStart Link]
 +
| You can use the ELK-M1XEP Ethernet Interface to connect the panels to Vera on the Ethernet port.
 +
|-
 +
| GE Security / Interlogix / Caddx
 +
|  
 +
*[http://www.interlogix.com/resources/intrusion/906-3179_NetworX_brochure.pdf NetworX NX-4]
 +
*[http://www.interlogix.com/resources/intrusion/906-3179_NetworX_brochure.pdf NetworX NX-6]
 +
*[http://www.interlogix.com/resources/intrusion/906-3179_NetworX_brochure.pdf NetworX NX-8]
 +
*[http://www.interlogix.com/resources/intrusion/906-3179_NetworX_brochure.pdf NetworX NX-8E]
 +
 
 +
| [http://utcfssecurityproducts.com/ProductsAndServices/Pages/NX-584.aspx NX-584]
 +
| [http://code.mios.com/trac/mios_caddxnx584/wiki/WikiStart Link]
 +
| NetworX NX-8E already has a RS-232 interface, so it doesn't require the NX-584 module.
 +
|-
 +
| Honeywell / Ademco
 +
| VISTA-50P, VISTA-128BP, VISTA-128BPT, VISTA-128BPE, VISTA-128FBP, VISTA-250BP, VISTA-250BPT, VISTA-250BPE and VISTA-250FBP
 +
| VISTA-50P, VISTA-128BP, VISTA-128FBP, VISTA-250BP, and VISTA-250FBP panels require the [http://www.security.honeywell.com/me/intrusion/products/exp/ac/138478.html 4100SM] module.
 +
| [http://code.mios.com/trac/mios_ademco-panels-plugin/wiki/WikiStart Link]
 +
| If your Vista panel is not on this list, look at the next row.
 +
|-
 +
| Honeywell / Ademco
 +
| 10SE, 20SE, 10P, 15P, 20P, 50P, etc.  
 +
| [http://www.nutech.com/online-store/18.html AD2USB]
 +
| [http://code.mios.com/trac/mios_vista-alarm-panel-ad2usb/wiki/WikiStart Link]
 +
| <br>
 +
|-
 +
| Paradox
 +
|
 +
*Digiplex DGP-848
 +
*EVO48
 +
*[http://www.paradox.com/Products/default.asp?CATID=7 EVO192]
 +
 
 +
| [http://www.paradox.com/Products/default.asp?CATID=7&SUBCATID=75&PRD=234 PRT3 Integration Module]
 +
| [http://code.mios.com/trac/mios_paradox-alarm/wiki/WikiStart Link]
 +
| <br>
 +
|-
 +
| Visonic
 +
|
 +
*[http://www.visonic.com/Products/Wireless-Property-Protection/PowerMax PowerMax]
 +
*[http://www.visonic.com/Products/Wireless-Property-Protection/PowerMaxPlus PowerMax+]
 +
*[http://www.visonic.com/Products/Wireless-Property-Protection/PowerMaxComplete PowerMaxComplete]
 +
*[http://www.visonic.com/Products/Wireless-Property-Protection/PowerMaxPro PowerMaxPro]
 +
 
 +
| RS-232 Interface Module
 +
| [http://code.mios.com/trac/mios_visonic-powermax/wiki/WikiStart Link]
 +
| <br>
 
|}
 
|}
  
=== '''Door Locks''' ===
+
<br>
  
{| border="1" cellpadding="2"
+
=== Misc  ===
! Manufacturer !! Device Type !! Model no. !! Version !! Date Purchased !! Location (indoor/outdoor) !! Specs !! Product Review !! Notes
+
 
 +
{| class="wikitable"
 
|-
 
|-
|| Schlage || Door lock and deadbolt || || || || Indoor ||  ||  || Read the instructions here: [[Schlage_Lock]]
+
! Manufacturer
 +
! Device Type
 +
! Model no.
 +
! Version
 +
! Frequency
 +
! Date Purchased
 +
! Location (indoor/outdoor)
 +
! Specs
 +
! Product Review
 +
! Added by User
 +
! Notes
 +
|-
 +
| Everspring
 +
| Door Bell<br>
 +
| UTSE03A<br>
 +
| <br>
 +
| EU
 +
|  
 +
|  
 +
|  
 +
|  
 +
|  
 +
| When added to a third party Z-Wave controller there is no way to associate the push button with the door bell itself, so the push button has no use. In order to make it work, the door bell needs to be associated with a regular Z-Wave switch either by creating associations or by creating a scene.
 
|}
 
|}
 +
 +
[[Category:User_Instructions]] [[Category:Hardware]]

Latest revision as of 18:39, 2 September 2013

This is a page for Supported Z-Wave devices.

Alternative hardware pages exist for

In general, any device with the Z-Wave logo should work with Vera. A list of tested Z-Wave devices is below, with specific notes for each type of device. This is a wiki, so feel free to add to the page. To learn about Z-Wave routing and fixing routing problems see: Heal Network

Contents

[edit] Hardware Reported to Work

  • We strongly encourage users to list any and all products they tested and installed.
  • If a product works but you did not like it, please list it anyway. It may be the only product available to some users.



IMPORTANT! The devices listed here have been added by installers, technicians and users like yourself. Results may vary upon installations. MiCasaVerde does not guarantee operation and compatibility with your installation. The listed devices were found to work with their specific installation. Mixing different series and brands of equipment is not guaranteed in any way to work with other series and brands. It is very likely that users have not fully tested all features of the devices, so it is possible that a device listed here as compatible, will not prove compatible with your hardware. If you are editing this wiki DO NOT REMOVE a listed working device if it hasn't worked for you. Seek help to get the device to work under your individual circumstance. If you are adding to this wiki, please provide links to data for the device and add any tips you feel may benefit someone wanting to implement the device into an installation.



[edit] Lighting Devices

Manufacturer Device Type Model no. Version Date Purchased Location (indoor/outdoor) Specs Product Review Added by User Notes
ACT 2-way Dimmer Switch ZDW120
Nov 2008 Indoor Link Link WSeverino Works well, easy to install, LED is a very bright blue....can be programmed to be off when the light is off or on. "series 200" model supports Group Associations 2 & 3. (The older "series 100" supported Groups 1-4, but is no longer available.)
ACT 3-way Dimmer Switch ZDW103
Nov 2008 Indoor Link Link WSeverino Works well, can be tricky to install due to the different combination of 3 way circuits, LED is a very bright blue....can be programmed to be off when the light is off or on.
ACT 2-wire Dimmer Switch ZDW232
Jul 2010 Indoor Link Link Newb Wall-mount, 230v, 500W, 2-Wire (no neutral), works well. Can be programmed to be off when the light is off or on.
ACT 2-way Relay Switch ZRW113
Nov 2008 Indoor Link Link WSeverino Controls Florescent Lamps very well! No humming at all.
ACT Companion Switch AS101
Nov 2008 Indoor Link Link WSeverino Works well, can be tricky to install due to the different combination of 3 way circuits, The trick here is to install this device where the power comes in.
ACT
3-way Dimmer Switch, 2 rocker
ZDM230
1.1
Aug 2009
Indoor
Link

TedStriker
Dimmer, Wall-mount, 230v, 500W,
3-way, 3 Wire, 2 rocker
ACT 3-way Relay Switch, 2 rocker ZRM230
1.1
Aug 2009
Indoor
Link

TedStriker
Relay, Wall-mount, 230v, 6A,
3-way, 3 Wire, 2 rocker - Status polling does not work with Vera
Cooper Accessory (3-way slave)


Indoor


See Cooper Accessory Slave
Düwi 2 wire dimmer

July 2011 Indoor

intveltr In-wall dimmer.
Düwi 3 wire switch 05431
July 2011 Indoor

intveltr In-wall switch.
Düwi 3 wire switch 06431
July 2011 Indoor

intveltr The newer in-wall Düwi switch (also designated Düwi.me), marked with a green sticker on the housing. This switch supports status push.
Fibar 3 wire double switch FGS221
Oct 2011 Indoor

intveltr This device is designed to use (and be mounted behind) existing light switches. Supports status push. Also available: single switch, dimmer, blind control.
GE/Jasco Lamp Module w/Dimmer 45602   7/2011 Indoor       Works with most incandescent bulbs.
GE/Jasco Fluorescent Light & Appliance Module 45603   7/2011 Indoor       Works with small appliances, incandescent, fluorescent and LED bulbs.
GE/Jasco Outdoor Switch Module 45604   7/2011 Outdoor       Works with small appliances, incandescent, fluorescent and LED bulbs.
GE/Jasco On/Off/Dim Dimmer Switch 45606   2/2011 Indoor Link Link   Anthonyris Discontinued, See 45612. Requires neutral lead. Works fine with most bulbs. With Philips AmbientLED, flickers at >95% brightness. Supports beaming. Flickers at low-levels with dimmable LED.
GE/Jasco Dimmer Switch 45607     Indoor        
GE/Jasco On/Off Switch 45609   7/2011 Indoor        
GE/Jasco Auxiliary Switch 45610   7/2011 Indoor       No zwave function; for 3 and 4-way switching kits
GE/Jasco 2-way Rocker Dimmer 45612   2/2012 Indoor       No neutral required; replaces 45606
GE/Jasco 3-way Dimmer Kit 45613     Indoor       Possible error in 45613 manual diagrams, see 45610 diagrams
GE/Jasco 3-way Switch Kit 45614   7/2011 Indoor        
Innovus Relay Switch Adapter RAone SmartPower   Aug 2009 Indoor Link   TedStriker Works very well + it has a build in powermeter which works perfect with Vera
Innovus Dimmer Switch Adapter RAone SmartDimmer   Aug 2009 Indoor Link   TedStriker Works very well + it has a build in powermeter which works perfect with Vera
Intermatic Lamp Module HA03C   Sept 2010 Indoor Link
JonnyO Easy to Instal, supports dimming
Intermatic Screw-in Lamp Module HA05C
Nov 2008 Indoor/Outdoor Link Link WSeverino Easy install, easy to pair with Vera!
Intermatic 300 watt dimmer HA06
July 2007 Indoor Link

Affordable Dimmer Switch. incandescent/halogen only. Loads for 300 watts or less no neutral required. Great for dimming one bulb.
Intermatic 3-way Switch HA18
Dec 2008 Indoor Link
Kozanator Affordable 3-way Switch
Intermatic 3-way Dimmer Switch HA20
Nov 2008 Indoor Link Link
Affordable 3-way 600W dimmer
Leviton Dimmer Switch VRI06-1LX   Aug 2009 Indoor Link
guessed Works well
Leviton 4-Scene Controller with Switch VRCS4-MRX 7,2,67,0,2 Aug 2009 Indoor Link
guessed Works well, pair as per Leviton 4-Scene Controller, then again holding "2" and "4" to pair the Switch ("Load") itself.
Leviton Dimmer Switch VRM10-1LX 1 Nov 2008 Indoor Link Link mark-hc This is a high quality dimmer geared towards high-end installations
Leviton Scene capable 3-way switch (non-dimming) VRS15-1L   May 2011 Indoor Link
DaveL17 (Coordinating Remote??)
Leviton Scene capable 3-way switch (non-dimming) VRS15-1LX   Oct 2011 Indoor Link
DaveL17 Works well. Pair normally. Can also be used in single pole applications. [Note: white, ivory, Almond.]
Leviton Scene capable 3-way switch (non-dimming) VRS15-1LZ     Indoor Link
DaveL17 Works well. Pair normally. Can also be used in single pole applications. [Note: white, ivory, Light almond.]
Merten Radio sensor cover for dimmer inserts 5026xx, 5036xx, 5046xx 6,2,7,1,5 Apr 2009 Indoor Link   Ap15e Works well
Merten Radio sensor cover for dimmer inserts 5026xx, 5036xx, 5046xx 6,2,7,1,5 Apr 2009 Indoor Link   Ap15e Works well
Merten Single Radio flush-mounted receiver 507001 6,2,27,2,2 Apr 2009 Indoor Link   Ap15e Works well
Merten switch, flush-mounted 507501, 507601     Indoor Link   Ap15e Works well (according to Link)
Merten 1-gang universal dimmer, flush-mounted 507900     Indoor Link   Ap15e Works well (according to Link)
Monster 4-Scene Controller with Switch IWC600
Dec 2011 Indoor Link

This is the same as the Leviton scene controller. Follow these instructions: Leviton 4-Scene Controller
Mvava Touch Based Light Switch (EU) MVA1102   Feb 2013 Indoor
photo
  nullx8 available in 1,2 and 3 Gang,
no Immediate Update of status changes
requires Neutral wire,

nice and good quality finishing,
Switched load 2x1100VA
website for contacts, currently no z-wave product info
company has not much knowledge about z-wave, but they do produce Switches on a large scale, the product is much more solid and does not provide the typical DYI feeling by installing or using it, screws for cables are very strong and can easy hold 6qmm cables.
Schlage Lamp Module RP200 1.0 Aug 2009 Indoor Link
LibraSun Works well
Sold with Schlage LiNK lock system
TKB Home 1 Way Switch TZ66-S   Jun 2013 Indoor Link   nullx8 Switches 1x 1360VA (6A), has additional Input for extra switch, easy to include,
no immediate Update to Controller of status change, LED's very discrete, EU Form only
TKB Home 1 Way Switch
Plus extra z-wave switch
TZ66-D   Jun 2013 Indoor Link   nullx8 Switches 1x 1360VA (6A), can control other z-wave switch/dimmer via assignment, has additional Input for extra switch, easy to include,
no immediate Update to Controller of status change, LED's very discrete, EU Form only


[edit] Plug & Receptacle Devices

Manufacturer Device Type Model no. Version Frequency Date Purchased Location (indoor/outdoor) Specs Product Review Added by User Notes
ACT In-Wall Receptacle ZRR150W 2.2   Nov 2008 Indoor Link Link
Works like a champ! Easy to Install. One receptacle RF controlled, the other is hot
ACT In-Wall Receptacle ZRP200   EU July 2011 Indoor     intveltr Basic plug-in switch.
ACT In-Wall Receptacle ZDP200   EU July 2011 Indoor     intveltr Basic plug-in dimmer.
Cooper Wiring Devices In-Wall Receptacle RFTR9505-T       Indoor Link

One receptacle is RF controlled, the other is hot. Not load sensing.
Duwi Z-Wave switch 3500 W 05437   EU Feb 2009 Indoor Link
ezhome High quality Plug-in switch, Easy install and works well
Easy-Light Z-Wave Switch 10A ZSL301   EU Feb 2013 Indoor Link
nullx8 Large Casing, extremly Solid, Switches incoming current trough
Easy-Light Z-Wave Dimmer 0.7A ZDL301   EU Feb 2013 Indoor Link
nullx8 Large Casing, extremly Solid, Switches incoming current, Dimms in 10% steps
Everspring Z-Wave switch 3500 W AN157-2 4,2,64,1,2 EU   Indoor Link
Ap15e Works well.
Everspring Z-Wave switch 3500 W AN158   EU   Indoor  
intveltr Works well. Supports status push and power metering
GE/Jasco In-wall Duplex Receptacle 45605   US 2/2011 Indoor Link Link   Anthonyris Easy. Works.
Home Manageables Lamp Module (Dimming) HM-LM001     Nov 2011 Indoor 200W maximum load, 25W minimum load Link DaveL17 Works well. Support for incandescent loads only. Not load sensing.
Intermatic In-Wall Receptacle CA3500 1   Nov 2008 Indoor Link Link
This is a decent, but expensive solution for in-wall receptacles. One receptacle RF controlled, the other is hot.
Intermatic Appliance Module HA02C 1   Nov 2008 Indoor Link Link
Seems to work well
Intermatic Outdoor Module HA04C 1   Dec 2008 Outdoor Link Link Kozanator Easy to Install.
Merten switch, plug adapter, 2000 W 508519 6,2,7,1,5 EU   Indoor Link   Ap15e Works well.
Monster Central 1800W Appliance Module ML-LAS1000 1   Jan 2009 Indoor Link
guessed Easy to Install. I use this as a ZWave signal repeater. Appears to be a badge-engineering of Leviton VRP15-1LW
Wayne Dalton Appliance Module HA-02L
(HA-02WD)


Dec 2011 Indooor Link
DaveL17 Note: link is to HA-02WD manual.
Wayne Dalton Lamp Module HA-03WD

Dec 2011 Indoor Link
DaveL17 Not load sensing.
Wayne Dalton Outdoor Lighting Module HA-04WD

Oct 2012 Outdoor Link
DaveL17 Not load sensing.


[edit] Thermostat Devices

Manufacturer Device Type Model no. Version Frequency Date Purchased Location (indoor/outdoor) Specs Product Review Added
By User
Notes
Wayne Dalton Wall Stat WDTC-20  ??   Nov 2008 Indoor Link Link
Has 2 inclusion modes: 1) press and release the bind button and the STAT will be included as a thermostat and works with Vera, 2) press and hold the bind button and it will be added as a binary switch for compatibility with old, non-compliant remotes. If it's added in the wrong mode, remove it and re-add it. Works great simple to use!
HAI Wall Stat RC-80BZ  ??   Nov 2007 Indoor Link Link
Shows up as Standard Thermostat in Vera, Hold button feature not able to control by Vera at this time. Priced above 200.00. Has internal setback programs. Works great.
RCS Wall Stat TZ43  ??   Nov 2008 Indoor Link Link
Shows up as Standard Thermostat in Vera, much more feature rich the the WDTC-20 but comes with a hefty price tag ($214.95). Wish Vera could use all the features in this Thermostat! Note:You need to set the thermostat to show the temperature, on its display, in Celsius degree in order to be able to receive "Set Temp" commands from Vera. This is no longer required in firmwares above 1.0.862 (luup)
Schlage/Trane Wall Stat Trane  ??    ?? Indoor Link Link
It's the same thermostat as the RCS TZ43 and it has the same issue: it's accepting "Set Temp Point" commands only in the measurement unit that is displayed on its screen. Note:You need to set the thermostat to show the temperature, on its screen, in Celsius degree in order to be able to receive "Set Temp" commands from Vera. This is no longer required in firmwares above 1.0.862 (luup)
Intermatic InTouch CA8900
  Nov 2008 Indoor Link

Looks very similar to the Wayne Dalton WDTC-20 listed here. works great, simple to use
Danfoss Radiator thermostat RA PLUS-w
EU
Indoor Link Link Link [1]
See: Danfoss Thermostat for installation instructions
If the device cannot be configured at the final location, move the device closer to Vera and try again (this device might require a direct connection to Vera for configuration).
Radio Thermostat Wall Stat CT22
US
Indoor Link Link
Daniel

To include the thermostat into your network, you just have to install the USNAP module in the thermostat while Vera is in Include mode. To exclude the thermostat from your network, you just have to install the USNAP module in the thermostat while Vera is in Exclude mode.You can watch a video about how to install it here

Radio Thermostat Wall Stat CT30
US

Indoor


mcvflorin
If you experience a problem with other Z-Wave devices, see this note.
Remotec Wall Stat ZTS-100


Indoor


To include the thermostat into your network, hold the home button for 2 seconds until the display says 'noc', which means 'no connection', then press the Prog button and the readout will say 'Srh'. If it doesn't say 'noc' or if the radio icon is visible in the upper right corner, the thermostat is already included and must be removed/reset. To remove/reset the thermostat hold the home button for 2 seconds until the display says 'done', then press the Prog button.
Horstmann Wall Stat HRT4-ZW
EU
Indoor Link Link
Daniel After you include the thermostat in Vera's network, you will have to make some configuration changes in order for it to report the temperature change. See: HRT4-ZW for more information.


[edit] Sensors

Manufacturer Device Type Model no. Version Frequency Date Purchased Location (indoor/outdoor) Specs Product Review Added by User Notes
ACT Motion Sensor ZIR000 / ZIR010
EU (ZIR010) or US (ZIR000)
Indoor Link Link Link Link

Remove the cover, pair to Vera's dongle by using the push-button on the left of the circuit board. Vera must configure it to work, and it can only be configured within less of a minute (30 sec best) of inserting the batteries. With Vera's dongle removed, remove/reinsert the batteries, and within 30 seconds insert Vera's dongle. Within a few minutes confirm the "configure" icon for the device is green on Vera's setup page
Aeon Labs 3-in-1 sensor (light/humidity/temperature) MultiSensor
EU or US
Indoor/Outdoor Specs

Pair to Vera by using the push-button. Vera must configure it to work, and it can only be configured within 10 minutes of inserting the batteries.
Express Controls aka HomeSeer 3-in-1 sensor (light/temperature/motion) HSM100 / EZMotion
EU or US

Link

See ExpressControls3in1
If the motion sensor does not work right after inclusion and configuration, remove the batteries for a few seconds.
EverSpring/Hawking/Home Manageables Door/window sensor SM103 6,2,9,1,0 EU or US Apr 2009 Indoor Link Link   Ap15e Pair using the intrusion button. The sensor will accept configuration within a few minutes of the initial pairing, or of pressing the intrusion button on the back even after it's paired. Pair the device, or if it's already paired, press the intrusion button, and within 30 seconds insert Vera's dongle. Within a few minutes confirm the "configure" icon for the device is green on Vera's setup page. NOTE: There is some confusion about the orientation of the sensor. The main sensor body has a back (where the intrusion is), a front (where the logo and LED is), and the 2 other surfaces, one of which has a curved edge, and the other is flat. The magnet needs to go against the flat surface. And the flat surface on the magnet should be as close as possible to the flat surface on the sensor, lined up in the middle so the line which passes through the LED lines up with the sensor.

Note: In case the inclusion/exclusion fails you should remove/reinsert the batteries from the sensor and within a few seconds the sensor should be automatically detected.

EverSpring/Home Manageables Humidity + Temperature sensor HM-TS001

Jan 2010 (requires version 1.1.0 or greater) Indoor Link Link   micasaverde Pair or unpair the device by tapping the CF button 3 times very quickly. Once it's paired and shows up in the UI as a generic device, press the CF button 3 times again quickly to make it wakeup and get configured. Then it will correctly be identified as 3 devices (combo device + temperature + humidity).
Everspring Motion Detector SP103 6,2,9,1,0 EU or US Apr 2009 Indoor Link Link   Ap15e Works well
Fortrezz Water /Freeze WWA-001  ?????? US Apr 2009 Indoor Link Link
Zmistro Works great I would place a few in your house. Bathrooms, laundry , kitchen , basement. Great product!
Intermatic Motion Sensor CA-9000
US
Indoor Link

Aaron This device has limited functionality as a sensor. It can only be used to turn on and off a light directly by setting an association, which Vera supports. It does not fire events, so you cannot use it as an event on a scene.
Merten 4-gang radio transmitter, flush-mounted 506004 2,2,27,1,4 EU   Indoor Link   Ap15e Note: There is proprietary functionality here. Support will be added soon.

Quite complex device; partially supported by Vera; can be used as a window/door sensor (as of firmware 1.0.900) ...

Aeon Labs (Aeotec)
4 in 1 Sensor (Multisensor)
DSB05106-ZWUS
US

Indoor/Outdoor
Link

mcvadi
Link


[edit] Door Locks

Manufacturer Device Type Model no. Version Date Purchased Location (indoor/outdoor) Specs Product Review Added
By User
Notes
Schlage Door lock and deadbolt BE369 (deadbolt)
Mid 2009 Indoor Link
LibraSun Read the instructions here: Schlage Lock
Kwikset Door lock and deadbolt


Indoor


Read instructions here:Kwikset Lock
Yale Deadbolt Real Living

Indoor

Link

Link



Read instructions here: Yale Lock


[edit] Drapes/Blinds

Manufacturer Device Type Model no. Version Date Purchased Location (indoor/outdoor) Specs Product Review Added
By User
Notes
Electronic Solutions Drape/Blind Motor Controller DBMZ V2+1
Indoor For 12-24VDC Motors Link Shady 2-Wire Motors
Electronic Solutions Drape/Blind Motor Controller ABMHZ V2+1
Indoor For 110-230VAC Motors Link Shady 4-Wire Motors
Lagotek / RSSceneAutomation Drape/Blind Motor Controller DC1-ZW

Indoor For 12-24VDC Motors Link Shady 2-Wire Motors
Lagotek / RSSceneAutomation Drape/Blind Motor Controller AC1-ZW

Indoor For 110-230VAC Motors Link Shady 4-Wire Motors


[edit] Relay controls

Manufacturer Device Type Model no. Version Date Purchased Location (indoor/outdoor) Specs Product Review Added
By User
Notes
Intermatic Contactor control box CA3750
Nov 2007 Indoor/Outdoor Link

Multi-instance class supported for this device. Vera is able to control each of the 2 relays independently if desired. please note unit shows as three switches this is a bug with Intermatic not a real issue.You can check the box in devices to not show the second listing of the first relay in "Dasboard" You can control heavy loads like a water heater ,pool pump motor/s. great device
Fibaro
Relay Switch
FGS211
EU
Link
Daniel This device is identified as a master device with 1 child device. The master controls the S1 output, the child controls the S2 output.
Fibaro Double Relay Switch FGS221
EU
Link
Daniel This device is identified as a master device with 1 child device. The master controls the S1 output, the child controls the S2 output.


[edit] Window Coverings

Manufacturer Device Type Model no. Version Frequency Date Purchased Location (indoor/outdoor) Specs Product Review Added by User Notes
Merten Radio roller shutter push-button 5025xx, 5035xx, 5045xx 6,2,27,2,3 and 6,2,27,2,4 EU Apr 2009 Indoor Link   Ap15e Open/Close buttons work well, but slide bar does not work. GUI buttons do not work with Luup release 1.0.843 and 1.0.862 (fixed with Luup release 1.0.879).
Workaround: Use a Luup Scene with the following code:

local lul_arguments = {}

lul_arguments["newTargetValue"]="0"

lul_resultcode,lul_resultstring,lul_job,lul_returnarguments = luup.call_action("urn:upnp-org:serviceId:SwitchPower1","SetTarget",lul_arguments,6) Replace "6" with your device number, replace "0" with "1" for inverse action.

Duewi Radio roller shutter push-button 054368 6,2,51,1,0 EU Jun 2009 Indoor Link   Lutz Open/Close buttons work well, but slide bar does not work.

Some additional observations by Ap15e (Vera V1, firmware 1.0.979):
  • GUI button 'Stop' and corresponding UPnP service does not work.
  • GUI button 'Up' moves the shutter down, GUI button 'Down' moves the shutter up ...
  • After adjusting the running times even the slide bar seems to work!
  • I got a report from a user that the düwi device may fail due to interference from the shutter motor. In this case an additional filter is required (costs about 25 €/direction).
  • More information is available at Link


[edit] Cameras that work

See IP Cameras for a more comprehensive and up to date list

Manufacturer Device Type Model no. Version Date Purchased Location (indoor/outdoor) Path for JPEG image Product Review Notes
Linksys IP Camera WVC54GCA all 2009 Indoor img/snapshot.cgi
An inexpensive camera with moderate image quality. Use the Linksys setup wizard for initial setup, then copy IP address and path into Vera setup fields. Use a static IP address.
Linksys IP Camera WVC210 all 2009 Indoor img/snapshot.cgi
A more expensive camera with good image quality and pan/tilt ability. Use the Linksys setup wizard for initial setup, then copy IP address and path into Vera setup fields. Use a static IP address. Pan/tilt controls will not work with Vera.
Linksys IP Camera WVC80N all 2009 Indoor img/snapshot.cgi?size=2&quality=1
A more expensive camera with good image quality and wireless N. Use the Linksys setup wizard for initial setup, then copy IP address and path into Vera setup fields. Use a static IP address. Pan/tilt controls will not work with Vera.

Size can be (160 x 120 = 1,320 x 240 = 2,640 x 480 = 3) and Quality can be (Very High= 1,High= 2,Normal= 3,Low= 4,Very Low= 5)

iCamView IP Camera Server iCV-22, iCV-32 all 2009
Indoor/Outdoor pda.cgi?user=admin&password=1234&page=image&cam=1

pda.cgi?user=admin&password=1234&page=image&cam=2

Feature-rich IP camera server, suports up to two compatible USB cameras, optional WiFi support, USB storage, USB hubs, motion; works with range of cameras, see icamview.co.uk. Excellent modular solution. They do ship to North America.
SmartHome.com.au IP Camera Z~Series Wireless Camera all 2009
Indoor tmpfs/auto.jpg
Inexpensive IP security camera designed for the Australian and New Zealand Z-Wave users, but shipping world wide.
LevelOne IP Camera WCS-2030 all 2010 Indoor cgi-bin/video.jpg CNET review An inexpensive IP camera with good image quality. Can be connected wired or wirelessly. Most LevelOne cameras use the same path for the JPEG image, so most of their line (both low and high end) should be compatible. Video and audio also stream over RTSP, which can be customized through the camera's web interface.
Asante IP Camera Voyager I firmware 2.02 and above 2010 Indoor image.cgi
An inexpensive IP camera that is very feature rich, has good image quality, night vision capabilities, motion detection, two-way audio, video streaming over TCP, UDP, or HTTP, and other configurable features. In firmware version 2.02, Asante added the capability to retrieve an image via a URL (however, it is delayed by 3 seconds). Offers a full-featured web interface in IE using an ActiveX plug-in (limited capabilites in other browsers).


[edit] Alarm Panels

Manufacturer Model(s) Required module Plugin Notes
DSC IT-100 or Envisalink IP170/2DS Link
Elk The M1EZ8 panel requires the ELK-M1EZ8MSI Main Serial Port Interface. Link You can use the ELK-M1XEP Ethernet Interface to connect the panels to Vera on the Ethernet port.
GE Security / Interlogix / Caddx NX-584 Link NetworX NX-8E already has a RS-232 interface, so it doesn't require the NX-584 module.
Honeywell / Ademco VISTA-50P, VISTA-128BP, VISTA-128BPT, VISTA-128BPE, VISTA-128FBP, VISTA-250BP, VISTA-250BPT, VISTA-250BPE and VISTA-250FBP VISTA-50P, VISTA-128BP, VISTA-128FBP, VISTA-250BP, and VISTA-250FBP panels require the 4100SM module. Link If your Vista panel is not on this list, look at the next row.
Honeywell / Ademco 10SE, 20SE, 10P, 15P, 20P, 50P, etc. AD2USB Link
Paradox
  • Digiplex DGP-848
  • EVO48
  • EVO192
PRT3 Integration Module Link
Visonic RS-232 Interface Module Link


[edit] Misc

Manufacturer Device Type Model no. Version Frequency Date Purchased Location (indoor/outdoor) Specs Product Review Added by User Notes
Everspring Door Bell
UTSE03A

EU When added to a third party Z-Wave controller there is no way to associate the push button with the door bell itself, so the push button has no use. In order to make it work, the door bell needs to be associated with a regular Z-Wave switch either by creating associations or by creating a scene.
Personal tools