Everspring Sensors

Inclusion:

Device File(s) known to work with Everspring Sensors:

Device

Device File(s)

ST814 Temperature/Humidity Sensor
ST815 Illumination Sensor with LCD D_ComboDevice1.xml

Setting Device Parameters:

To set device parameters on Everspring devices:

  1. In Vera's UI, click on the wrench for the device and select the 'Device Options' tab (see below). 
  2. Select 'Add configuration settings' and add your first parameter (you can add only those parameters that you want to set). 
  3. After you have added the parameter values that you want to set within Vera, select SAVE, and the refresh your browser. 
  4. Wake up the Everspring device (for example, on the ST815 Illumination Sensor, press the ESC/[L] button 3 times within 1.5 seconds).  The device will stay awake for 10 seconds.
  5. Select 'Configure node right now' on the device's 'Settings' tab within Vera.



Example of Parameter Settings for ST815 Under UI5



Everspring ST815 Illumination Sensor with LCD

Parameter Function Size
(Byte)
Value Unit Default Set
(Factory Default)
Description
1 Basic Set Level 1 dec 0-99 Percent of Brightness (Dimmer Level) 99 (99) Set basic set value to be on (or set Lux Level)/off.
0: Disable
2 Lux Trigger - On Value 2 dec 30-1000 or 0 LUX 300 (0) Set Lux trigger-ON Value to be _Lux.
0: Clear Lux trigger-ON value
3 Lux Trigger - Off Value 2 dec 30-1000 or 0 LUX 500 (0) Set Lux trigger-OFF Value to be _Lux.
0: Clear Lux trigger-OFF value
4 Lux Trigger - Off (Timer Value) 2 dec 1-480 or 0 Minute 240 (0) Set Lux trigger-OFF Value to be _Lux.
0: Clear Lux trigger-OFF value
5 Auto Report (Time Interval) 2 dec 1-1439 or 0 Minutes 0 (0) Set auto report time interval to be _mins.
6 Auto Report (Lux Interval) 2 dec 30-1000 or 0 LUX 0 (0) Enable auto report.
0: Disable auto report.