'''Alarm Panel Plugins'''
 +
 
=== DSC PowerSeries Panels ===
 
=== DSC PowerSeries Panels ===
  
Line 59: Line 64:
  
  
=== Honeywell Ademco Vista Panels ===
+
=== Honeywell Ademco Vista Panels with RS232 Interface ===
  
N/A
+
'''Author:''' dfad1469
 +
 
 +
'''Compatible models:''' all Honeywell/Ademco alarm panels with a RS232 interface.
 +
 
 +
'''Interface:''' serial (RS232)
 +
 
 +
'''UPnP services, variables and actions used:'''
 +
 
 +
* urn:micasaverde-com:serviceId:VistaAlarmPanel1
 +
** '''Variables:'''
 +
*** ActivePartitions
 +
*** ActiveZones
 +
*** EventLog
 +
** '''Actions:'''
 +
*** SendCommand
 +
* urn:micasaverde-com:serviceId:AlarmPartition2
 +
** see [[Alarm Panel Standardization#S_AlarmPartition2.xml]]
  
  

Latest revision as of 08:38, 8 September 2011


Alarm Panel Plugins

Contents

[edit] DSC PowerSeries Panels

Authors: Javier Guerra, guessed

Compatible models: PC1616, PC1832, PC1864

Hardware requirements: IT-100 Integration Module

Interface: Serial (RS232)

UPnP services, variables and actions used:

  • urn:micasaverde-com:serviceId:DSCAlarmPanel1
    • Variables:
      • ActivePartitions
      • DoorZones
      • MotionZones
      • SmokeZones
      • LCD
      • FireKeyAlarm
      • AuxKeyAlarm
      • PanicKeyAlarm
      • AuxInputAlarm
      • FirmwareVersion
    • Actions:
      • SyncTime
      • SendCommand
  • urn:micasaverde-com:serviceId:AlarmPartition2


[edit] Elk M1 Panels

Authors: mcvflorin

Compatible models: M1 Gold, M1EZ8

Hardware requirements: ELK-M1EZ8MSI (only for M1EZ8)

Interface: Serial (RS232)

UPnP services, variables and actions used:


[edit] GE/Caddx NetworX Panels

Authors: futzle

Compatible models: NX-4, NX-6, NX-8, NX-8E

Hardware requirements: NX-584 (only for NX-4, NX-6, NX-8)

Interface: Serial (RS232)

UPnP services, variables and actions used:


[edit] Honeywell Ademco Vista Panels with RS232 Interface

Author: dfad1469

Compatible models: all Honeywell/Ademco alarm panels with a RS232 interface.

Interface: serial (RS232)

UPnP services, variables and actions used:


[edit] Paradox EVO Panels

Authors: guessed

Compatible models: EVO48, EVO192

Hardware requirements: PRT3 Integration Module

Interface: USB