1. Unplug your Black Zwave dongle from Vera's USB port.</br>
+
1. Unplug your Black Zwave dongle from Vera's USB port.<br>
2. Locate it's part number (it's written on the back of it). If it's: DSA02203-ZWUS/EU proceed further.</br>
+
2. Locate it's part number (it's written on the back of it). If it's: DSA02203-ZWUS/EU proceed further.<br>
3. The procedure can be done only on a Windows PC from an account that has Administrative privileges (Administrator account).</br>
+
3. The procedure can be done only on a Windows PC from an account that has Administrative privileges (Administrator account).<br>
3.1. To see the type of your account go to: Start->Control Panel->Users (User Accounts)</br>
+
3.1. To see the type of your account go to: Start->Control Panel->Users (User Accounts)<br>
3.2. If you are an "Limited Account" you can't proceed further. Log-out and login into an account that is "Computer Administrator"</br>
+
3.2. If you are an "Limited Account" you can't proceed further. Log-out and login into an account that is "Computer Administrator"<br>
4. Download the Windows drivers for the Zwave Stick:</br>
+
4. Download the Windows drivers for the Zwave Stick:<br>
4.1. Go to: https://www.silabs.com/products/mcu/Pages/USBtoUARTBridgeVCPDrivers.aspx</br>
+
4.1. Go to: https://www.silabs.com/products/mcu/Pages/USBtoUARTBridgeVCPDrivers.aspx<br>
4.2. Download VCP Driver Kit :</br>  
+
4.2. Download VCP Driver Kit :<br>  
Windows 2000/XP/2003/Vista: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=23</br>
+
Windows 2000/XP/2003/Vista: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=23<br>
Windows 7: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=24</br>
+
Windows 7: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=24<br>
Linux: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=25</br>
+
Linux: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=25<br>
MacOS: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=26</br>
+
MacOS: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=26<br>
4.3. If you don't have an unzip program (a program to extract the zip archive) grab 7zip from here: http://www.7-zip.org/</br>
+
4.3. If you don't have an unzip program (a program to extract the zip archive) grab 7zip from here: http://www.7-zip.org/<br>
4.3.1. Download 7-Zip 4.65 http://downloads.sourceforge.net/sevenzip/7z465.exe</br>
+
4.3.1. Download 7-Zip 4.65 http://downloads.sourceforge.net/sevenzip/7z465.exe<br>
4.4. Extract the CP210x_VCP_Win2K_XP_S2K3.zip archive and run CP210x_VCP_Win2K_XP_S2K3.exe</br>
+
4.4. Extract the CP210x_VCP_Win2K_XP_S2K3.zip archive and run CP210x_VCP_Win2K_XP_S2K3.exe<br>
4.4.1. Install the Drivers.</br>
+
4.4.1. Install the Drivers.<br>
5. Plug the black Zwave dongle in your PC USB PORT</br>
+
5. Plug the black Zwave dongle in your PC USB PORT<br>
6. Download the Upgrade Utility: http://www.aeon-labs.com/site/products/view/2/</br>
+
6. Download the Upgrade Utility: http://www.aeon-labs.com/site/products/view/2/<br>
EU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=22</br>
+
EU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=22<br>
US: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=21</br>
+
US: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=21<br>
AU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=38</br>
+
AU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=38<br>
6.1. Run it</br>
+
6.1. Run it<br>
7. Keep pressed the Zwave Stick button and press the UPGRADE button on the utility</br>
+
7. Keep pressed the Zwave Stick button and press the UPGRADE button on the utility<br>
  
 
Note: If you get a message that the Zwave stick is not found  you should set a correct baud rate also:
 
Note: If you get a message that the Zwave stick is not found  you should set a correct baud rate also:
  
- Start -> My Computer: right click on it and then Device Manager</br>
+
- Start -> My Computer: right click on it and then Device Manager<br>
- In Device Manager - expand Ports and right click on Silicon Labs CP210x USB to UART Bridge then Properties.</br>
+
- In Device Manager - expand Ports and right click on Silicon Labs CP210x USB to UART Bridge then Properties.<br>
- in this  windows go to  Port Settings and set:</br>
+
- in this  windows go to  Port Settings and set:<br>
 
  Bits per second: 115200
 
  Bits per second: 115200
 
  Data bits: 8 Parity: None
 
  Data bits: 8 Parity: None
Line 48: Line 48:
 
==References==
 
==References==
 
please find more info here;
 
please find more info here;
http://forum.micasaverde.com/index.php?topic=2857.0</br>
+
http://forum.micasaverde.com/index.php?topic=2857.0<br>
http://forum.mios.com/index.php?topic=2857.msg11457#msg11457</br>
+
http://forum.mios.com/index.php?topic=2857.msg11457#msg11457<br>
  
 
==Downloads==
 
==Downloads==
 
Firmwares;
 
Firmwares;
EU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=22</br>
+
EU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=22<br>
US: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=21</br>
+
US: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=21<br>
AU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=38</br>
+
AU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=38<br>
  
 
Upgrade utility:
 
Upgrade utility:
http://www.aeon-labs.com/Z-Stick_US_502P3_091124.exe</br>
+
http://www.aeon-labs.com/Z-Stick_US_502P3_091124.exe<br>
  
 
Driver kits:
 
Driver kits:
Windows 2000/XP/2003/Vista: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=23</br>
+
Windows 2000/XP/2003/Vista: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=23<br>
Windows 7: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=24</br>
+
Windows 7: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=24<br>
Linux: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=25</br>
+
Linux: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=25<br>
MacOS: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=26</br>
+
MacOS: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=26<br>

Revision as of 14:49, 18 August 2011


HOW TO Upgrade the z-wave firmware of your AEON-Labs usb dongle

Contents

Prerequisites

  • 1 Firmwareupgradeable AEON-LAbs usb dongle (DSA02203-ZWUS/EU)
  • The VCP driver kit for your client (Windows / Linux / MacOS)
  • Most recent compatible firmware from AEON-Labs

Introduction

Heres a short manual on how to upgrade the z-wave firmware on an AEON-Labs us dongle.

Instructions

1. Unplug your Black Zwave dongle from Vera's USB port.
2. Locate it's part number (it's written on the back of it). If it's: DSA02203-ZWUS/EU proceed further.
3. The procedure can be done only on a Windows PC from an account that has Administrative privileges (Administrator account).
3.1. To see the type of your account go to: Start->Control Panel->Users (User Accounts)
3.2. If you are an "Limited Account" you can't proceed further. Log-out and login into an account that is "Computer Administrator"
4. Download the Windows drivers for the Zwave Stick:
4.1. Go to: https://www.silabs.com/products/mcu/Pages/USBtoUARTBridgeVCPDrivers.aspx
4.2. Download VCP Driver Kit :
Windows 2000/XP/2003/Vista: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=23
Windows 7: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=24
Linux: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=25
MacOS: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=26
4.3. If you don't have an unzip program (a program to extract the zip archive) grab 7zip from here: http://www.7-zip.org/
4.3.1. Download 7-Zip 4.65 http://downloads.sourceforge.net/sevenzip/7z465.exe
4.4. Extract the CP210x_VCP_Win2K_XP_S2K3.zip archive and run CP210x_VCP_Win2K_XP_S2K3.exe
4.4.1. Install the Drivers.
5. Plug the black Zwave dongle in your PC USB PORT
6. Download the Upgrade Utility: http://www.aeon-labs.com/site/products/view/2/
EU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=22
US: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=21
AU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=38
6.1. Run it
7. Keep pressed the Zwave Stick button and press the UPGRADE button on the utility

Note: If you get a message that the Zwave stick is not found you should set a correct baud rate also:

- Start -> My Computer: right click on it and then Device Manager
- In Device Manager - expand Ports and right click on Silicon Labs CP210x USB to UART Bridge then Properties.
- in this windows go to Port Settings and set:

Bits per second: 115200
Data bits: 8 Parity: None
Stop bits: 1
Flow Control: none

References

please find more info here; http://forum.micasaverde.com/index.php?topic=2857.0
http://forum.mios.com/index.php?topic=2857.msg11457#msg11457

Downloads

Firmwares; EU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=22
US: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=21
AU: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=38

Upgrade utility: http://www.aeon-labs.com/Z-Stick_US_502P3_091124.exe

Driver kits: Windows 2000/XP/2003/Vista: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=23
Windows 7: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=24
Linux: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=25
MacOS: http://www.aeon-labs.com/site/public/lib/download.php?type=s&f=26

Personal tools